Functional description
53
Welding device factory settings
Fig. 46: Overview of System application / factory settings
The factory settings are set by pressing the push and rotate knob twice. The
programs and the settings in the System application are retained.
Welding parameters
Factory setting
Gas preflow time
0.1 s
Ignition current
50%
Start current
50%
Upslope time
0.1 s
Current I1
100 A
Current I2
80 A
Pulse time t1
0.3 s
Pulse time t2
0.3 s
Downslope time
0.1 s
End crater current
20%
Gas post-flow time
5.0 s
AC frequency*
Automatic
AC balance*
- 65%
Ignition
HF on
Operating mode
2 step
Polarity*
DC Minus
EL current I1
150 A
Hot-Start current
70%
Arc Force current
70%
Pulse type
Pulses off
Pulse frequency
500 Hz
* not used in DC systems
Fig. 47: Factory settings overview