Regency
®
U39EX ULTIMATE™ Freestanding Gas Stove
|
3
table of contents
On Demand Pilot (seven day safety timer)
Important information if using the appliance in CPI (continuous pilot mode) only
This appliance is a Dexen control system fitted with the “On Demand” Pilot, a safety feature which will shut down the gas valve completely by extinguishing the
pilot light in the event of a continuous full seven days of inactivity.
This only applies if the CPI (continuous pilot) switch is in the “on” position in your remote control transmitter.
Each time the main burner shuts down, manually or through the call from the thermostat, the seven day timer starts again.
The seven day inactivity timer is controlled within the circuit board. Therefore, if in CPI mode and when the pilot light is extinguished after seven straight days
of inactivity, the CPI setting on the remote control transmitter will remain in the “CPI” (continuous pilot) position. Therefore, all that is required to relight the
pilot would be to press the on/off button on the remote control transmitter from “on” to “off” and back to “on”. Once the pilot has re-established operation will
resume as normal. There is no requirement to do anything with the IPI/CPI mode on the remote control transmitter.
If the unit never goes as long as seven full days without a call for heat, the pilot will remain lit until it is manually shut-off.
If the unit is being operated in IPI (intermittent pilot) mode, neither the above instructions nor the seven day timer will apply.
See the instructions in this manual and on the Lighting Instructions plate on the appliance to light or re-light the pilot.
Owner’s Information
Copy of Safety Label for U39EX Gas Stove
.............5
Decal Location .....................................................5
Before You Start
...................................................8
Lighting Procedure ...............................................9
Shutdown Procedure
............................................9
Copy of the Lighting Plate Instructions
...................10
Remote Control Operating Instructions
..................11
Back Up Battery
...................................................15
Warranty .............................................................58
Dimensions
Unit Dimensions ...................................................4
Installation
Gas Installation Checklist
......................................6
Important Information
..........................................17
Specifications
.......................................................17
Information For Mobile/
Manufactured Homes After First Sale
.....................17
General Safety Information
...................................18
Installation Checklist
.............................................18
Clearances To Combustibles
..................................18
Manufactured Mobile Home Requirements
..............19
Locating Your Ultimate Gas Stove
..........................19
Louver Installation ................................................19
Combustion And Ventilation Air
.............................19
Safety Screen Installation
.....................................19
Venting Introduction
.............................................19
Exterior Vent Terminal Locations
............................20
4” x 6-5/8” Rigid Pipe Cross Reference Chart
..........21
Rigid Pipe Venting Systems
...................................23
Installation Precautions .........................................24
Safety Precautions for the Installer
........................24
Rigid Pipe Venting Arrangements
...........................25
DV Stove Horizontal Vent Kit Installation
................27
Dura-Vent Termination Kit
.....................................29
Dura-Vent Venting Components
.............................29
Dura-Vent Horizontal Terminations
.........................30
Dura-Vent Vertical Terminations
.............................31
Cathedral Ceilings
.................................................32
Converting a Class-A Metal Chimney to a
Direct Vent System
...............................................33
Converting a Factory Built Metal Chimney
...............33
System Date ........................................................34
Gas Connection
....................................................34
High Elevation
......................................................34
Conversion from NG to LP
.....................................35
Conversion to High Elevation
.................................37
Gas Pipe Pressure Testing .....................................37
Dexen Valve Description
.......................................38
Aeration Adjustment .............................................38
On Demand Pilot Light ..........................................38
Log Set Installation ..............................................39
Driftwood Log Set Installation
...............................42
Wiring Diagram with Optional Wall Thermostat
.......45
Operating Instructions
First Fire ..............................................................46
Operating Instructions ..........................................46
Remote Control Wall Mount Holder/Cradle
..............46
Operation using an Optional Wall Thermostat .........46
Backup Battery
.....................................................47
Automatic Convection Fan Operation
.....................48
Adjusting Flame Height
.........................................48
Normal Operating Sounds of Gas Appliances
..........48
Maintenance
Maintenance Instructions ......................................49
Flame Pattern ......................................................49
Log Replacement .................................................50
Door Gasket
........................................................50
Latch Adjustment .................................................50
Glass Replacement ...............................................50
Panel Glass Replacement ......................................50
Installing Glass .....................................................50
Fan Maintenance ..................................................51
To Remove Fan from Front of Unit
.........................51
Replacing U39EX Fan ............................................51
Valve Replacement
...............................................52
Gas Maintenance ..................................................53
Troubleshooting ...................................................54
Parts
Main Assembly .....................................................55
Burner & Log Assembly.........................................56
Door Assembly .....................................................57
Warranty
Warranty .............................................................58
Installer’s information
Содержание Ultimate U39EX
Страница 62: ...62 Regency U39EX ULTIMATE Freestanding Gas Stove warranty ...
Страница 63: ......