52
|
Regency
®
U39EX ULTIMATE™ Freestanding Gas Stove
maintenance
Valve Replacement
If the valve requires maintenance or replacement,
use the following instructions:
Note: Always shut off the gas supply and
turn off electrical before removing
the valve.
1. Remove safety screen and open front pedestal
door. You may want to put a soft cloth on the
base of the unit so that when the pedestal door
is open it doesn't scratch the paint.
2. Remove chain from door and unit,remove 4
screws holding the access panel in place.
7. Remove all 18 screws holding the burner tray
assembly in place.
8. Carefully lift the valve tray assembly out.
9. Remove the valve tray and replace.
10. Reverse Steps 1 to 8 to complete.
3.
Disconnect 10-pin connector, the spark ignition
wire, flame sensor wire from control module.
ttoooollttiipp
4. Disconnect the gas at the valve. Access through
the front (with access panel removed). The gas
line may also accessed by removing the rear
pedestal cover plate.
5. Carefully remove the logs and lava rock.
Location of Control
Module
10-pin
Connector
Flame Igniter
Flame Sensor
6. Remove two (2) screws to remove burner. Note:
Use a magnetic type screwdriver if possible.