Regency
®
U39EX ULTIMATE™ Freestanding Gas Stove
|
25
installation
Rigid Pipe Venting Arrangements
Vertical Termination Systems for
Residential Manufactured and
Mobile Homes
The shaded area in the diagram below shows
all allowable combinations of straight vertical
and offset to vertical runs with vertical
terminations.
Maximum two 45
o
elbows
.
If the vent is ENCLOSED in a chase (min. size 9"
x 9") maintain a 1-1/4" clearance to combustibles.
May be installed in Manufactured (Mobile)
Homes after first sale.
Horizontal Terminations for All
Venting Systems
The shaded areas in the diagram below
show all allowable combinations of vertical
runs with horizontal terminations. Maximum
one 90
O
elbow (two 45
o
elbows equal one
90
o
elbow).
Propane and Natural Gas:
Residential, Manufactured and
Mobile Homes Installations
May be installed in Manufactured (Mobile)
Homes after first sale.
Horizontal Run (Feet)
5'(1.5m) Min.
8'(2.4m)
5'(1.5m)
2' (.6m)
Min.
1'(0.3m)
10'(3m)Max.
13' (4.0m)
2
2
12
12
14
6
6
16
4
4
14
22
8
8
18
10
10
20
Vertical Height (feet)
20'-6"(6.2
)Max.
m
Horizontal Run (Feet)
5'(1.5m) Min.
8'(2.4m)
5'(1.5m)
3' (.9m)
Min.
1'(0.3m)
10'(3m)Max.
13' (4.0m)
1
1
2
2
12
12
14
6
6
16
4
4
14
22
8
8
18
10
10
20
Vertical Height (feet)
20'-6"(6.2
)Max.
m
0-2000'
NG - @38,000 Btu/hr #32
LP - @38,000 Btu/hr #49
0-4500'
NG - @35,000 Btu/hr #35
LP - @32,500 Btu/hr #51