U32S-5 FPI Direct Vent Gas Insert
15
installation
9
11/03/09
918-480d
E33S-1 / U32S
Installation of the DC Sparker:
1)
Locate the Piezo Ignitor situated at the
side of valve.
Piezo Ignitor
2)
Remove the Piezo Ignitor by unscrewing
the nut at the back of the mounting
bracket.
Ignitor Wire
Piezo Ignitor
3)
Disconnect the ignitor wire from the
Piezo Ignitor and connect it to the DC
Sparker.
Ignitor Wire
DC Sparker
4)
Connect the DC spark generator wires
to the SIT Valve with the screw, which is
provided in the kit.
5)
Locate the ground lug at the receptical
box, left of the unit.
6)
Connect one end of the supplied green
ground wire to the lug with the nut and
washer from the kit.
Ground wire from Kit
WARNING!
Do not overtighten the screw.
Recommended to
grip the wrench by the short side.
19)
Verify that if the conversion is from
NG to LPG, the screw must be re-
assembled with the red o-ring visible
(Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
21)
Attach the label "This unit has been
converted to Propane" near or on top of
the serial # decal.
22)
Replace yellow "Natural Gas" label with
red "LPG" label.
20)
Re-assemble the black protection cap
(Fig. 6).
WARNING!
Also check that the pilot and main
burner injectors
are appropriate for the gas type.
Fig. 6