U32S-5 FPI Direct Vent Gas Insert
17
installation
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
1)
Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fireplace to
that location. Use Thermostat Wire Table.
2)
Connect the wires as per the wiring diagrams
in this manual.
caution
do not connect the millivolt
remote control
the 120V wires.
3)
Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
final cHeck
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1)
Clocking the appliance to ensure the
correct firing rate (rate noted on label) at
15 minutes.
2)
If required, adjusting the primary air to
ensure that the flame does not carbon.
First allow the unit to burn for 15 min. to
stabilize.
3)
Check for proper draft.
caution
any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of
the manufacturer.
optional Wall
tHerMostat
A wall thermostat may be installed if desired,
follow the wiring diagram below. Regency offers
an optional programmable thermostat but any
250-750 millivolt rated non-anticipator type
thermostat that is CSA, ULC or UL approved
may be used.
caution
do not connect the millivolt wall
thermostat wires
to the 120V wires.
optional reMote
control
Use the Regency Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
recommended Maximum lead length
(two-Wire) When using Wall
thermostat (cp-2 system)
Wire size
Max. length
14 Ga.
50 Ft.
16 Ga.
32 ft.
18 Ga.
20 ft.
20 Ga.
12 ft.
22 Ga.
9 ft.