14
U32S-5 FPI Direct Vent Gas Insert
installation
8
11/03/09
918-480d
E33S-1 / U32S
7)
Remove burner orifi ce with a 1/2" wrench
and discard.
8)
Install the new LP burner orifi ce stamped
#54 and tighten.
9)
Pull off the pilot cap to expose the pilot
orifi ce.
10)
Unscrew the pilot orifi ce with the
supplied allen key and replace it with
the LP pilot orifi ce and re-install the pilot
cap.
14)
From the valve remove the black protec-
tion cap by hand from the high-low knob
(Fig.1).
Fig. 1
15)
Insert the allen key
into the hexagonal
key-way of the
screw (Fig. 2),
rotate it counter-
clockwise until it is
free and extract it.
Fig.2
16)
Check that the screw is clean and if
necessary remove dirt.
17)
Flip the screw (Fig. 3).
18)
Using the allen key as shown in Fig.4,
rotate the screw clockwise until snug, do
not overtighten.
Fig.3
Fig.4
11)
Re-install base cover.
12)
Re-install burner and back shield.
13)
Reinstall pilot cover
Burner Orifi ce -
E33S
Burner Orifi ce -
U32S
Lift up from the back.
LP Aeration Settings -
set before
reinstalling burner.
E33S
1/4"
U32S
Glass Crystals Spa Stones
1/2"
3/8"