16
U32S-5 FPI Direct Vent Gas Insert
installation
10
11/03/09
918-480d
14)
Tie up the loose wire with the wire clip.
13)
Find a location which is not too hot and
is easy to reach for changing the battery.
See image below as an example.
Installer Notice:
These instructions must be left
with the appliance.
15)
Check for gas leaks with a proper soapy
solution or leak detector.
16)
Check for proper spark between the
ignitor and pilot cap. Refer to "Lighting
Procedure" section of the manual for
lighting sequence.
17)
Check inlet (12" WC min) and outlet
(11" WC) pressures. Refer to "Gas Pipe
Pressure Testing" section of the manual.
18)
Check for proper fl ame appearance.
10)
Connect the ground wire to the DC
Sparker mounting bracket.
12)
Mount the heat shield to the DC Sparker.
Secure into place with the velcro, which
is provided in the kit.
11)
Install the supplied battery into the DC
Sparker Box by opening the battery
compartment.
NOTE:
The battery in the DC Sparker
Box will need to be replaced annually.
Battery
Compartment
E33S-1 / U32S
7)
Install the 1/2" bushing to the heat
shield.
Heat Shield
8)
Run the other end of the ground wire
and DC spark generator wires through
the bushing on the heat shield.
9)
Plug the DC spark generator wires to the
DC Sparker.
Note:
It should be kept away from the
chain
(U32S only).
Chain