40
|
Regency
®
P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace
|
40
maintenance
12) Lift the entire assembly out.
8) Remove the Side Base Brick Panels and
finally the Long Base Brick Panels.
Remove Left & Right Side Base
Brick Panels
Remove the 2 Long Base Brick Panels
9) Disconnect the inlet gas line.
10) Disconnect the 2 TP wires and the 2 TH
wires from the valve.
11) Remove the 16 Phillips head screws
securing the valve tray.
13) Undo the pilot tube from the valve with a
7/16" wrench.
14) Undo the quick drop out thermocouple nut
on the valve with a 9mm (metric) wrench.
15) Remove the DC sparker assembly.
16) Undo the "gas out" flare nut with a 13/16"
wrench.
17) Undo the "gas out" flare fitting with an
11/16" wrench.
18) Remove the 6 Phillips head screws from
the sides of the valve bracket and remove
valve.
Hint: If you are using black pipe, ensure
that there is a union by the valve,
otherwise removal will be almost
impossible.
REMOVING VALVE
1) Shut off the gas and electrical supply.
2) Remove the louvers and trim kit. Remove
the safety screen and glass door.
3) Remove the logs, embers.
4) Remove the grate by lifting straight up.
7) Slide the burner assembly away from the
orifice and lift out.
5) Remove the side brick clip in the top of the
firebox and then slide the Side Brick Panel
out.
The brick panels are very fragile
- handle with care.
6) Remove the burner by removing the 4
screws.