18
|
Regency
®
P121-10/P131-10 Zero Clearance Direct Vent Gas Fireplace
|
18
installation
23
VENTING ARRANGEMENT - HORIZONTAL TERMINATIONS
Regency
®
Direct Vent System (Flex) Horizontal Terminations Only
These venting systems, in combination with the P121-10/P131-10 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater
system by Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in the "Exterior
Vent Termination Locations" section.
Regency
®
Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the P121-10/P131-10 with a
maximum run of 2 feet.
If installing the P121-10/P131-10 with a
continuous
vent length of more than 2 ft. (.6m) to a maximum of 10 ft. (3.0m)
use Kit # 946-515 (4 ft.) or 946-516 (10 ft.)
1)
6-7/8" dia. flexible liner (2 ft. length)
2)
4" dia. flexible liner (2 ft. length)
3)
spring spacers (3)
4)
thimble (2)
5)
AstroCap
termination cap (1)
6)
screws (12)
7)
tube of Mill Pac (1)
8)
plated screws (8)
9)
screws #8 x 1-1/2" drill point, stainless steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency
®
may be used for Flex installations.
3) Regency
®
Direct Vent System (Flex) is only approved for horizontal terminations.