LOG SET INSTALLATION

Read the instructions below carefully and refer to the 

diagrams.  If logs are broken do not use the unit until 

they are replaced. Broken logs can interfere with the  

pilot operation.

Log Kit # 360-930 contains the following pieces:

a)  326  Front Right Log  

b)  327  Front Left Log   

c)  328  Middle Right Log 

d)  329  Middle Left Log  

e)    

Embers (902-154)

f)    

Platinum Embers (946-669) - 

supplied with pack- 

 

aged manual

The 3-digit numbers (ie. 327) are molded into the rear of each log.

326

327

329

328

Please note that there are 2 of each log. 

This log set is mirrored front and back.

326

Push back side of the left end of the log up 

against the tab on the burner.

327

Grate Post

3)

  Place Log 326 on the front right side of the burner. 

Ensure that the notches on the far right side of the log 

fi t into the grate posts. Push back side of the left end 

of the log up against the tab on the burner.

Repeat step 3 on the opposite side of the burner.

4)

  Place Log 327 on the front left side of the burner. Po-

sition the right end of the log in between the two tabs 

and the left end of the log into the grate post.

918-111c

01/03/08

LOG SET INSTALLATION

P121 / P131

Page 1 of 2

Tab on Burner

IMPORTANT

When placing Embers, do not block burner ports 

as this can cause an incorrect fl ame pattern, 

carbon deposits and delayed ignition.

2)

  Place embers on the burner as shown below. 

 

Separate platinum embers and place on the burner 

over top of and around embers. Platinum embers can 

cover burner ports. Avoid stacking platinum embers.

1)

 Carefully remove the logs from the box and unwrap 

them.  The logs are fragile, handle with care - 

do not 

force into position.

326

326

Содержание P121-LP10

Страница 1: ...Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach y...

Страница 2: ...el P121 P131 has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace IMPORTANT If the unit is to be installed into a bathroom optional Neo ceramic g...

Страница 3: ...ode ANSI Z223 1 and the current National Electrical CodeANSI NFPA70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency mobile manufactured home listed appliance comes factory equipped with four 1 4 diameter holes located near each corner of the base Fasten the fireplace in place using screw inserted through the ...

Страница 4: ... Fan Replacement 41 P121 10 See Thru Main Assembly 42 P131 10 Pier Main Assembly 43 P121 10 P131 10 Burner Assembly Log Set 44 Warranty 47 Copy of Safety Decal 5 Dimensions 7 General Safety Information 10 Installation Checklist 10 Locating Your Gas Fireplace 11 Clearances 12 Combustible Mantels 12 Framing And Finishing 13 Unit Assembly Prior To Installation 14 Venting Introduction 14 Exterior Vent...

Страница 5: ...ith the Standard CAN CSA Z240 MH Mobile Housing in Canada or with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 in the United States or when such a standard is not applicable ANSI NCSBCS A225 1 NFPA 501A Manufactured Home Installations Standard or ANSI A119 2 ou NFPA501C Standard for Recreational Vehicles This appliance is only for use with the type of gas indicated...

Страница 6: ...ove grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unles...

Страница 7: ...Regency P121 10 P131 10 Zero Clearance Direct Vent Gas Fireplace 7 7 dimensions P121 10 See Thru Note These units are non load bearing ...

Страница 8: ...8 Regency P121 10 P131 10 Zero Clearance Direct Vent Gas Fireplace 8 dimensions P131 10 Pier Note These units are non load bearing ...

Страница 9: ...BARRIERS IS RECOMMEND ED IF THERE ARE AT RISK INDIVIDUAL IN THE HOUSE TO RESTRICT ACCESS TO A FIREPLACE OR STOVE INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS YOUNG CHILDREN AND OTHER AT RISK INDIVIDUALS OUT OF THE ROOM AND AWAY FROM HOT SURFACES IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Panorama P121 P131 NG10 or P121 P131 LP10 Direct Vent Fireplace must be installed in accordance with t...

Страница 10: ...e manufacturer GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149orANSI Z223 1Installation Codes 2 See general construction and assembly instructions The appliance and vent should be enclosed 3 This appliance must be connected to the specifiedventandterminationcaptotheoutsi...

Страница 11: ... extending the full width and depth of the appliance 4 The Direct Vent Gas Fireplace can be installed as follows Model Position A P121 10 See Thru B P131 10 Pier 5 This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P121 10 P131 10 Direct Vent Gas Fireplace is approved f...

Страница 12: ...d floor eg tile carpet slate to allow the finished surface to be flush with the base of the unit Ceiling Height from Floor 72 1828mm Mantel Height from Base of Unit 39 min 991mm Horizontal Vent Clearances Top 2 1 2 64mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Vent Clearances 1 1 4 32mm Becauseoftheextremeheatthisfireplaceemits the mantel clearances are critical Combustible mantel clearances fro...

Страница 13: ...otal facing thickness can vary from 1 2 13mm to 1 1 4 32mm thick 2 When locating your appliance on an exterior wall or in a chase apply a vapour barrier and drywall as per local building codes DO NOT INSULATE THE FIREPLACE ITSELF CAUTION The unit does not have to be completely enclosed in a chase The clearance on top of the unit is 0 to the standoffs so combustible building materials can be laid d...

Страница 14: ...rohibited See RigidPipeVenting Systems for more details and exceptions UNIT ASSEMBLY PRIOR TO INSTALLATION The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position Top Standoff Assembly The top standoffs are shipped in a flat position and must be folded into shape and attached 1 Removethestandoffsfromthefireplacetop 2 Take each standoff and bend...

Страница 15: ...f center line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway ...

Страница 16: ...N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A Extension Pipe 16 Black 46DVA 16AB...

Страница 17: ...orizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guar...

Страница 18: ... System Termination Kit Part 946 513 includes all the parts needed to install the P121 10 P131 10 with a maximum run of 2 feet If installing the P121 10 P131 10 with a continuous vent length of more than 2 ft 6m to a maximum of 10 ft 3 0m use Kit 946 515 4 ft or 946 516 10 ft 1 6 7 8 dia flexible liner 2 ft length 2 4 dia flexible liner 2 ft length 3 spring spacers 3 4 thimble 2 5 AstroCap termina...

Страница 19: ...th inches Required inches 4 5 1 2 6 7 8 1 2 9 10 11 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Pipe When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent Ameri can Metal Products Ameri Vent D...

Страница 20: ...amples of horizontal termination arrangements using one two or three 90o elbows two 45o elbows equal one 90o elbow Note 1 A maximum of three 90o elbows are permitted 2 Minimum distance between elbows is 1 ft 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing thr...

Страница 21: ...in 3 914mm Max 6 1 86m Max C 4 1 22mm Min 5 1 5m Max 9 2 7m Max D 5 1 5m Min 7 2 13m Max 12 3 6m Max Withtheaboveoptions maximumtotalpipelengthif37feetwithminimum of 5 feet total vertical and maximum 12 feet total horizontal Please note minimum 1 foot between 90o elbows is required Option V H H H1 A 1 305mm Min 1 305mm Max 3 914mm Max B 2 610mm Min 3 0 91m Max 6 1 86m Max C 3 914mm Min 5 1 5m Max ...

Страница 22: ...r Propane and Natural Gas as per diagram 7 below Straight Up Vertical Venting Vertical Venting with One 1 90o Elbow Diagram 8 IMPORTANT When installing this unit vertically the 45o elbow when installed in conjunction with the Rigid Pipe Adaptor will protrude past the unit 1 1 2 38mm when measured from the rear standoffs Note A 1 1 4 32mm clearance from the elbow must also be maintained Option V H ...

Страница 23: ... D 4 1 22m Minimum 8 2 4m Maximum With the above options maximum total pipe length if 37 feet with minimum of 6 feet total vertical and maximum 17 feet total horizontal Please note minimum 1 foot between 90o elbows is required With the above options maximum total pipe length if 37 feet with minimum of 4 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o ...

Страница 24: ... see diagram in the Exterior Vent Termination Locations section 6 The arrow on the vent cap should be pointing up Insure that the 1 1 2 clearances to combustible materials are maintained Diagram 3 in the Venting Arrangement Horizontal Terminations section Install the termination cap The four wood screws provided should be replaced with appropriate fasteners for stucco brick concrete or other types...

Страница 25: ... Before connecting the horizontal run of vent pipe to the vent termination slide the Wall Thimble over the vent pipe 8 Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1 1 4 inches Secure the connection betw...

Страница 26: ...asier Apply Mill Pac or high temperature silicone to the 6 7 8 175mm flex pipe and slip it over the 6 7 8 outer collar of the vent terminal at least 1 3 8 35mm and fasten with the 3 screws NOTE Horizontal sections must be supported at intervals not exceeding 3 feet 0 9 meter Flame picture and performance will be affected by sags in the liner 4 Separatethe2halvesofthewallthimbleand securely fasten ...

Страница 27: ...way from the orifice and lift out 4 Remove the burner assembly by remov ing the 4 screws then slide the burner assembly away from the orifice and lift out 9 Reinstall new burner orifice LPG stamped 50 and tighten 10 Turn control knob to the OFF position Conversion from NG to LPG for P121 10 P131 10 using SIT 829 NOVA Gas Valve 3 Remove the grate by lifting straight up Remove the side brick panels ...

Страница 28: ...t side or the bottom of the appliance The gas valve is situated on the bottom of the unit Thegaslineconnectionmaybemadeofrigidpipe copper pipe or an approved flex connector If you are using rigid pipe ensure that the valve can be removedforservicing Sincesomemunicipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code Fo...

Страница 29: ... voltage junction box to the framing at desired location within 10 ft from fireplace 2 Feed the 12 pin connector through the opening at back of junction box 3 Connect the 12 pin connector to the back of the receiver 4 Install the Receiver in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 P...

Страница 30: ...ace Log 326 on the front right side of the burner Ensure that the notches on the far right side of the log fit into the grate posts Push back side of the left end of the log up against the tab on the burner Repeat step 3 on the opposite side of the burner 4 Place Log 327 on the front left side of the burner Po sition the right end of the log in between the two tabs and the left end of the log into...

Страница 31: ...f the Log onto the second grate post from the left Ensure that the log fits into a pin that is on Log 326 Repeat step 5 on the opposite side of the burner 6 Place Log 328 on the middle right side of the burner Ensure that the log fits over the 2nd grate post from the right Repeat step 6 on the opposite side of the burner 918 111c 01 03 08 LOG SET INSTALLATION P121 P131 Page 2 of 2 Grate Post 328 3...

Страница 32: ...2 Loosen 2 screws in locations shown in Diagram 1 Diagram 1 Diagram 5 Diagram 3 Diagram 2 Diagram 4 3 Lift top bracket up and outward to remove as shown in Diagram 2 5 Loosen the 2 screws as shown in locations shown in Diagram 4 6 Pull the bottom bracket down and outward to remove 4 Remove safety screen by lifting up and out 7 To install reverse steps ...

Страница 33: ...ensure that some room is left to be able to hang the grill or louver over the screw 2 Hang the Top Louver or Grill onto the 2 screws in the top fireplace opening 3 Attach the Bottom Louver or Grill to the hinges on the bottom flange of the fireplace 4 Attach the screws provided to the top and bottom left and right corners similar to step 1 5 Hang the top and bottom louver or grill onto the screws ...

Страница 34: ...e wires as per the wiring diagram Use the table below to determine the maximum wire length Note Preferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect millivolt wall thermostat wires to 120V wire Recommended Maxi...

Страница 35: ...ause improper and dangerous operation No electrical power supply is required for the gas control to operate 120 Volt AC power is needed for the fan switch and blower The fan can be hard wired if desired A terminal block is provided on the left hand side of the unit A three wire power cord can also be used and plugged into a suitable receptacle Do not cut the ground terminal off under any circumsta...

Страница 36: ...s coding See remote control instructions for details NOTE This appliance will operate during power outages Only the fan will not operate until power is restored If the remote batteries in boththehandheldtransmitterorreceiverlose power the appliance can still be operated by sliding the switch on the receiver switch from Remote to ON To turn on the appliance off slide the receiver switch from ON to ...

Страница 37: ...can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Un...

Страница 38: ... very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dullclickingsoundmaybeaudible thisisnormal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process During the first few fires a white f...

Страница 39: ...lass panels should be done by a licensed or qualified service per son GLASS REPLACEMENT In the event that you break your glass by impact purchase your replacement from an authorized Regencydealeronly Replacementglassisshipped already installed into the door frame Reinstall as per Glass Door Installation in the Glass Door Removal section REPLACEMENT PARTS Front Door Tempered Part 360 528 Side Door ...

Страница 40: ...sparker assembly 16 Undo the gas out flare nut with a 13 16 wrench 17 Undo the gas out flare fitting with an 11 16 wrench 18 Remove the 6 Phillips head screws from the sides of the valve bracket and remove valve Hint If you are using black pipe ensure that there is a union by the valve otherwise removal will be almost impossible REMOVING VALVE 1 Shut off the gas and electrical supply 2 Remove the ...

Страница 41: ...econnect the gas out flare nut with a 13 16 wrench 4 Install DC sparker assembly 5 Reconnectthequickdropoutthermocouple nut with a 9mm wrench 6 Reconnect the pilot tube nut with a 7 16 wrench 7 Scrapeofftheoldgasketfromthefloorofthe firebox and from the valve tray assembly 8 Install a new gasket and reinstall the valve tray assembly Note Failure to install a new gasket may severely affect the appl...

Страница 42: ...sket Relief Door 24 Relief Door Assembly 32 362 528 Brick Panel Base Set of 4 34 902 603 Brick Panel Std Red Side 135 360 069 Heat Shield Side 146 360 033 Left Side Door Trim 360 034 Right Side Door Trim 150 360 123 Magnet Bracket Front 151 904 258 Magnet 168 360 068 Door Cover Assembly Side 171 360 920 Louver Front Black set 360 924 Louver Front Black Steel set 181 Extension Trim See Thru 204 360...

Страница 43: ...ef Door 24 Relief Door Assembly 32 362 528 Brick Panel Base Set of 4 34 902 603 Brick Panel Side Std Red 141 360 031 Column Finishing Trim 146 360 035 Finishing Trim 149 360 122 Magnet Bracket Corner 150 360 123 Magnet Bracket Front 151 904 258 Magnet 171 360 920 Louver Front Black set 360 924 Louver Front Black Steel set 173 360 932 Louver Side Black set 360 936 Louver Side Black Steel set 181 Ex...

Страница 44: ...embly LPG 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 79 360 525 Burner Assembly 82 360 027 Grate Assembly 904 690 Orifice 31 NG 904 641 Orifice 50 LP 936 170 Orifice Gasket 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 910 581 Stepper motor NG 910 582 Stepper motor LP 910 432 Pilot tube with nuts 910 096 3 way pilot hood 910 341 Thermopile 910 386 Thermocouple 910 073 DC Spark box 910 07...

Страница 45: ...Regency P121 10 P131 10 Zero Clearance Direct Vent Gas Fireplace 45 45 notes ...

Страница 46: ...46 Regency P121 10 P131 10 Zero Clearance Direct Vent Gas Fireplace 46 notes ...

Страница 47: ...turned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement part...

Страница 48: ...______________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related product...

Отзывы: