HZ42 Regency Horizon
TM
Gas Fireplace
48
MAINTENANCE
VALVE ASSEMBLY REPLACEMENT
MAINTENANCE
1)
Turn the unit off and allow it to cool down to room temperature.
2)
Turn off the gas and power supply to the unit.
3)
Remove the faceplate by lifting it up off the glass door.
4)
Remove the glass door.
a)
Remove the 3 screws shown below at the bottom of the glass
door
.
b)
Swing the door out 45
o
from the bottom and lift up and out.
Faceplate
Glass Door
5)
Remove the pilot cover as shown below.
6)
Lift
out
fi rebox base cover.
7)
Remove three screws from locations shown below to release
burner.
Slide burner to the left to release from the orifi ce and lift out -
see inset.
8)
Disconnect the ON/OFF connector wires from the valve.
9)
Disconnect the DC Sparker leads at the valve.
DC Sparker Lead
ON/OFF Connector Wires
Содержание Horizon HZ42
Страница 53: ...HZ42 Regency HorizonTM Gas Fireplace 52 NOTES ...
Страница 54: ...HZ42 Regency HorizonTM Gas Fireplace 53 NOTES ...
Страница 55: ...HZ42 Regency HorizonTM Gas Fireplace 54 NOTES ...