HZ42 Regency Horizon
TM
Gas Fireplace
24
INST
ALLA
TION
INSTALLATION
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
V
H
V + V1
H + H1
With these options,
maximum total pipe
length is 30 feet with
minimum of 12 feet
total vertical and
maximum 9 feet total
horizontal.
P l e a s e n o t e
m i n i m u m 1 f o o t
between 90
o
elbows
is required.
A)
2' Min.
1' Max.
3' Min.
4' Max.
B)
3' Min.
2' Max.
4' Min.
5' Max.
C)
4' Min.
3' Max.
6' Min.
6' Max.
D)
5' Min.
4' Max.
8' Min.
7' Max.
E)
6' Min.
5' Max.
10' Min.
8' Max.
F)
7' Min.
6' Max.
12' Min.
9' Max.
Restrictor Position - Set 0 (factory setting)