installation
Grandview
®
G800C-1 Gas Fireplace | 43
Conversion to Top Vent
Note: This conversion must be done prior to the unit being
placed in position.
The unit comes equipped as a rear vent unit. These in-
structions are to be used, only if the unit is going to be
top vented.
Loosen
1. Remove six (6) screws in locations shown below to remove vent cover plate.
Vent cover plate
2.
Using a magnetic drill bit
—remove the two (2) top screws and loosen
two(2) bottom screws to remove
outside collar
from the back of the unit.
See Diagram 3.
3. Remove the four (4) top screws and loosen the two (2) bottom screws to
remove in the
inner collar
from the back of the unit. See Diagram 3.
Note: Tale care not to drop any screws into the unit.
Important:
Loosen bottom screws only and slide inner and outer collar up
and off unit.
Diagram 1
Diagram 3
Diagram 4 - Top of Unit
Diagram 2 - Back of Unit
4. From the top of the unit—remove the top cover plate by removing the two
(2) top screws and loosening the two (2) bottom screws. Slide cover plate
up and off to remove.
R e m o v e
outer collar
R e m o v e
screws
Diagram 5
5. Remove the insulation from the top of the unit as shown and discard.
f i r e - p a r t s . c o m