installation
Grandview
®
G800C-1 Gas Fireplace | 33
Outside Finish Installation (Non Cool Wall) - Mantel Clearances
Note: Ensure the paint that is used on the mantel and the facing is "High Quality" or the paint may discolour.
Due to the extreme heat this fireplace emits, the mantel clearances are critical.
Combustible mantel clearances from top of front facing are shown in
the diagram below.
Mantel Clearances
A
B
C
D
From Top of Fireplace
Opening
34"
(754 mm)
19"
(483 mm)
15"
(381 mm)
10"
(254 mm)
Combustible
Mantel Clearances
2
0
12
6
4
8
10
0
Top of
Fireplace
12"
1"
7"
A
B
14
To Floor
12
24
Inches
C
D
Non-Combustible Material
Min. 10" H (254mm)
Outside Finish Installation (Non Cool Wall) - Mantel Leg Clearances
Allowable mantel leg projection
TopView
Side opening
of fireplace
Mantel Leg
1-1/2"
(38 mm)
4-1/4"
(108mm)
6-7/8" (175mm)
3
5-7/8"
(
912
mm)
Overall Fireplace Width (Outside Finish)
3”
(76 mm)
Mantel Leg
**The non combustible board supplied with the appliance is 11-1/2" (292mm) high. This may be cut to size if desired.
f i r e - p a r t s . c o m