background image

MODELS:    P90E-NG11 Natural Gas     P90E-LP11 Propane

Excalibur

®

 P90E Zero Clearance  

Direct Vent Gas Fireplace

Owners & 

Installation Manual

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING
FIRE OR EXPLOSION HAZARD

failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

REGENCY FIREPLACE PRODUCTS.  6988 Venture St., Delta, BC  Canada, V4G 1H4

919-971a

04.05.19

Installer

:  Please complete the details on the back cover and leave this manual 

with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

Certified to/Certifié pour:     CSA 2.17-2017
                                            ANSI Z21.88-2017
                                            CSA 2.33-2017

Tested by : 

Содержание Excalibur P90E Zero

Страница 1: ...ighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD failure to follow safety warnings exactly could result in serious injury death or property damage REGENCY FIREPLACE PRODUCTS 6988 Venture St Delta...

Страница 2: ...nd has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model P90E 11 has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructi...

Страница 3: ...allation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada ThisExcalibur Mobile ManufacturedHomeListed...

Страница 4: ...ety feature which will shut down the gas valve completely by extinguishing the pilot light in the event of a continuous full seven days of inactivity This only applies if the CPI continuous pilot switch is in the on position in your remote control transmitter Each time the main burner shuts down manually or through the call from the thermostat the seven day timer starts again The seven day inactiv...

Страница 5: ...y Excalibur P90E 11 Direct Vent Gas Stove 5 dimensions ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS Unit Dimensions ...

Страница 6: ...us de renseignements Cet appareil ne peut pas être utilisé avec d autres gaz sauf si une trousse de conversion certifiée est fournie This vented gas fireplace heater is not for use with air filters Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation For use with glass doors certified with the appliance only À utiliser uniquement avec les portes en verre certifiées avec l appareil See...

Страница 7: ...ST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC ITISIMPERATIVETHAT CONTROLCOMPARTMENTS BURNERS ANDCIRCULATINGAIRPASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE...

Страница 8: ... seconds the spark ignition system will spark for 60 seconds to light the main burner 4 The unit will turn on Lighting Procedure Continuous Pilot Intermittent Pilot CPI IPI selection See remote control instructions for details On Demand Pilot seven day safety timer Important information if using the appliance in CPI continuous pilot mode only This appliance is a ProFlame 2 system fitted with the O...

Страница 9: ...e notice risque de déclencher un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant être mortelles Tout défaut d installation d ajustement de modification de service ou d entretien peut entraîner des blessures ou des dommages matériels Reportez vous au manuel d utilisation fourni avec cet équipement Pour obtenir de l aide ou des informations complémentaires c...

Страница 10: ...roflame Transmitter Figure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batterie...

Страница 11: ... flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room th...

Страница 12: ...roflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light ...

Страница 13: ...IPI to a continuous pilot ignition system CPI by using remote control as noted above The benefits of having as CPI are as follows Keeps venting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensa tion on start up Provides owners with flexibility to choose a traditional continuous pilot The primary benefit o...

Страница 14: ...grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless up...

Страница 15: ... local codes with the current Canadian or National Gas Codes CAN1 B149orANSIZ223 1Installation Codes 2 The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 See general construction and assembly instructions The appliance and vent shoul...

Страница 16: ... section 5 ThisapplianceisListedforbedroom installations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P90E 11 Direct Vent Gas Fireplace is approved for alcove installations which meet the clearances listed on this page 7 Werecommendthatyouplanyourinstallationon paperusingexactmeasurementsforclearances andfloorprot...

Страница 17: ...nsions from 45 1 4 up to 46 3 8 In the event that you should choose to use thinner materials to finish the hearth you can omit the standoffs provided for raising the unit However we recommend that you leave the framing dimensions as they are in the manual and alter only the facing requirement by reducing it by the same distance that you have lowered the unit Insert the 2 unit base standoffs undern...

Страница 18: ...ance Note Anon combustiblemantelmaybeinstalledat a lower height if the framing is made of metal studscoveredwithanon combustibleboard The non combustible mantle when installed at a lower overall height may not be lower than 6 inches from the top of the fireplace opening Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel ...

Страница 19: ...e surround when fitted must be lifted up and out in order to remove it Regency provides a template on the box NOTE If using a brick hearth the fireplace will need to be raisedtoaccommodatethebrick thickness Example Ifthebrickis 2 thick theunitmustberaised1 Note 48 1219mm is the minimum height for both flexterminationor RigidPipeventing 4 Note The unit does not have to be completely enclosedinachas...

Страница 20: ...ical studs and secure using pointed wood screws to pen etrate steel studs to secure There are 6 screws which are not provided 2 at bottom 2 at top and 2 on sides Corner framing shown in diagram NOTE Ensure the flat side of the steel stud is facing the wood framing 4 Slide the unit into position Hook up gas venting and electrical prior to installing the remaining steel studs 5 Secure the top horizo...

Страница 21: ...lder in the Low Voltage Junction box 5 Install batteries only if 120 volt power will not be used Batteries are only used if power is lost within the home and serve as a secondary power source Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Battery Holder switch in the OFF position to allow correct lineup for slid...

Страница 22: ...ct vent gas appliance must use it s own separate vent system Common vent systems are prohibited Side Nailing Strips The side nailing strips come attached to the unit There are 2 plates one on the top and bottom that can be folded out as required Plates can be folded out Unit Assembly Prior To Installation The 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipp...

Страница 23: ...hepartsneeded to install the P90E 11 with a maximum run of 4 feet 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 If a longer run is needed the FPI DirectVent system Flex kit is 946 516 which includes all the parts...

Страница 24: ...extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on pub...

Страница 25: ... Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanize...

Страница 26: ... 4ST36 N A Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK VDV K04 Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use wi...

Страница 27: ... A VDV WPT05 Wall Thimble Support Ceiling Support 58DVA DC N A from FPI N A N A N A N A Firestop Spacer 58DVA FS 5DT FS 5DFS TM 5LS VDV FS05 Trim Plate Black 58DAV WFS 5DT TP 5DCP TM 5TP VDV WTC05 5 X 8 RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed Not all rigid pipe components are available directly from Regency Note The listed manufacturers may have ot...

Страница 28: ...Rigid Pipe Adaptor Must use with all rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 B36XTE B36XTCE ONLY 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 5DDA must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 Not available applicable for the following units B41XTE B41XT...

Страница 29: ...hes Vent Length Required inches 4 5 1 2 6 7 8 1 2 9 10 1 1 2 12 9 14 1 2 11 14 5 8 Adj Pipe 15 23 1 2 17 24 Adj Corner Installation Wall Thickness inches Vent Length Required inches 3 1 4 6 3 4 11 14 5 8 Adj Pipe 7 3 4 16 1 4 17 24 Adj Pipe 7 1 4 8 3 4 6 12 9 9 4 1 4 5 3 4 6 9 When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI AstroCapT...

Страница 30: ...30 Regency Excalibur P90E 11 Direct Vent Gas Stove installation Horizontal Vertical Terminations for 5 x 8 Venting ...

Страница 31: ...s as listed in the Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard Part 946 506 P should be used whenever the termination is lower than the specified minimum or as per local codes Note FPIDirectVentSystem Flex isonlyapproved for horizontal terminations All Rigid Pipe Systems 5 inner diamet...

Страница 32: ...agram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbow with rigid pipe vent systems for Propane and Natural Gas The P90E 11 is approved for a maximum 40 ft straight vertical with rigid pipe4 x6 5 8 ventsystemsforPropaneandNaturalGas asperdiagram The shaded area in the diagram show all allowable combinations of straight vertical and offse...

Страница 33: ...x F 5 Min 7 Max G 6 Min 8 Max Must Use 5 x 8 Simpson DirectVent Piping with FPI Increaser Starter Collar Part 946 605 Must Use 5 x 8 Simpson Direct Vent Piping with FPI Increaser Starter Collar Part 946 605 One 90o elbow Two 45o elbows Option V H V V1 H H1 W i t h t h e s e options max total pipe length is 30 feetwithmin of12 feet total vertical and max 9 feet total horizontal Please note min 1 fo...

Страница 34: ...et with min of 6 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required For additional vertical venting with 2 x 90o elbows refer to the Rigid Pipe Venting Arrangements Horizontal Termination section Must Use 5 x 8 Simpson DirectVent Piping with FPI Increaser Starter Collar Part 946 605 Option V H H1 V V1 A 6 Min 2 Max 3 Min B 1 Min 2 Max 3 Min C ...

Страница 35: ...edown Diagram 3 Diagram 3a Note Riser Vent is only for use in above grade terminations NOTE For best results and optimum perfor mance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied toeveryinnerpipeconnec tion Failure to do so may result in drafting or performance issues not covered under warranty Note With DuraVent the m i n i m u m h e i g h t i s ac...

Страница 36: ...onnect the strips to the pipe section See Diagram 6 9 Installwallthimblein the center of the 10 square and attach with wood screws Diagram 7 3 A Firestop spacer must be installed in the floor or ceiling of every level To install the Firestop spacer in a flat ceiling or wall cut a 10 inch square hole Frame the hole as shown in Diagram 3 and install the firestop 4 Assemble the desired lengths of pip...

Страница 37: ...e to mount the terminal to Outside Wall Mur extérieur Furring Strips Fourrures en bois Furstrp eps see also c34020a eps furstrpf eps french Offset Chart Installation Procedures for FPI Direct Vent System Flex 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termi...

Страница 38: ...TION 4 X 6 7 8 VENTING VERTICAL FLEX VENT KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe l...

Страница 39: ...m 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level To instal...

Страница 40: ...dmanifoldpressuresshould becheckedusingthevalvepressure ports on the valve 1 Make sure the valve is in the OFF position 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attachmanometerto IN and or OUT pressure tap s using a 5 16 ID hose 4 Lightthepilotandturnthevalveto ON position 5 The pressure check should be carried out with the unit burning ...

Страница 41: ...ce Discard orifice Burner Orifice Remove the 2 screws push Burner Assembly to the left and lift out 3 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out Installer Notice These instructions must be left with the appliance 4 Remove the wire clip below the pilot cap Pilot retainer clip 5 Pull off the pilot cap to expose the pilot orif...

Страница 42: ...ng it between the back wall of the firebox and the rear log bracket 4 Put the side panels in next Slide them in from the front and push them flat up against the wall Be very careful not to scratch them on the firebox hardware 5 Install the 2 brick retaining clips one on each side Note If the bottom brick panel must be removed Remove the Rear Log Stand then remove the Burner Tray See the Removing V...

Страница 43: ...ere with the pilot operation The gas log kit Part 780 930 contains the following pieces a 02 75 Rear Log b 02 55 Middle Left Log c 02 50 Front Left Log d 02 53 Center Left Log e 02 51 Front Bottom Log f 02 54 Center Right Log g 02 52 Middle Right Log h 902 156 Embers i 902 179 Vermiculite j 946 669 Platinum Embers supplied with packaged manual NOTE If you will be installing the optional Brick Pane...

Страница 44: ...ay and rest the log on the cutout on Log 02 53 Cutouts 5th Grate Tab 02 54 0 2 5 3 02 51 6 Position Log 02 54 across the cutouts in Logs 02 51 and 02 53 The notch in the bottom right end fitting against the 5th grate tab 5 Position Log 02 53 across the cutouts in Logs 02 75 and 02 51 with the notch on the left side of the log fitting into the 2nd grate tab Cutouts 2nd Grate Tab 02 53 02 75 02 51 0...

Страница 45: ...ar Grate Tab 02 52 02 51 02 54 02 52 02 54 8 Place Log 02 52 between Logs 02 51 and 02 75 and on the indentation on Log 02 54 The bottom right end sits behind the rear grate tab Front Brackets Notch 02 50 02 53 02 50 02 55 02 53 9 Sit Log 02 50 on the front left side of the burner Push the back of the log against the 2 front brackets with the notch on the bottom of the log fitting into the first g...

Страница 46: ...efrontburneron and around the embers Avoid stacking platinum embers Platinum embers may be placed over burner ports 11 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports Do not block the burner ports in this area adjacent to the Log 02 54 02 51 02 54 IMPORTANT ...

Страница 47: ... contains the following pieces A Rear Log B Middle Left Log C Front Left Log D Center Left Log E Front Bottom Log F Center Right Log G Middle Right Log 902 156 Embers 902 179 Vermiculite 946 669 Platinum Embers supplied with packaged manual NOTE If you will be installing the optional Brick Panels install the Brick Panels prior to installing the logs Model shown P90 without Brick Panels installed 4...

Страница 48: ...ket on the burner tray and rest the log on the cut out on Log D Cutouts 5th Grate Tab 6 Position Log F across the cut outs in Logs E and D The notch in the bottom right end fitting against the 5th grate tab 5 Position Log D across the cut outs in Logs A and E with the notch on the left side of the log fitting into the 2nd grate tab Cutouts 2nd Grate Tab 5th Grate Tab D A E D A B D F E D ...

Страница 49: ...to show the positioning of Log G Rear Grate Tab 8 Place Log G between Logs E andAand on the indentation on Log F The bottom right end sits behind the rear grate tab Front Brackets Notch 9 Place Log C on the front left side of the burner Push the back of the log against the 2 front brackets with the notch on the bottom of the log fitting into the first grate tab G A C E C ...

Страница 50: ...d around the embers Avoid stacking platinum embers Platinum embers may be placed over burner ports 11 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports Do not block the burner ports in this area adjacent to the Log F IMPORTANT When placing Embers do not block ...

Страница 51: ...ithin unit as shown in diagram below 2 Line up surround so it is parallel with the unit lift surround slightly lower gently until upper tabs seat into upper slots on the bracket within the unit 3 To remove lift surround straight up then pull forward Note There is an access door at the bottom of the surround that can be opened by flipping down 90º Surround attached by lower tabs only Final install ...

Страница 52: ... but may need adjusting due to either the local gas supply or altitude Minimum Air Shutter Opening 3 16 Natural Gas 5 16 Propane CAUTION Carbon will be produced if air shutter is closed too much Note Any damage due to carboning resulting from improperly setting theaerationcontrolsisNOTcovered under warranty Note Aeration Adjustment should only be performed by an authorized Excalibur Installer at t...

Страница 53: ...ons This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong recep tacle Do not cut or remove the grounding prong from this plug Note 4 AA Batteries must be installed into the back up battery compartment however for this unit to operate when power is lost See battery back up instructi...

Страница 54: ...ferable if the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect the millivolt wall thermostat wires to the 120V wires Wiring Diagram with Optional Thermostat GREY GREY Thermostat Optional Millivolt EXTERNAL ANTENNA ...

Страница 55: ... The unit should never be turned off and on again without a minimum of a 60 second wait This remote control requires coding See remote coding instructions for details NOTE Thisappliancewilloperatewith4AAback up batteriesinstalled seeBack upBatterysection for details during power outages Only the fan and light will not operate until power is restored If the remote is misplaced the unit can be shut ...

Страница 56: ...screws 1 Remove 2 Phillips head screws to remove cover plate Place screws to the side Cover plate may not be exactly as shown See diagram 1 Diagram 2 Battery compartment door Battery compartment tabs 2 Press down on both tabs to remove battery compartment door See diagrams 2 and 3 Diagram 4 Diagram 3 Battery door removed 3 Install 4 AA batteries ensuring they are polarity correct See diagram 4 4 R...

Страница 57: ...TO THE HAZARDS OF HIGH SURFACE TEMPERATUREANDSHOULDSTAY AWAYTOAVOIDBURNSORCLOTH ING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPER VISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE 8 Each time the appliance is lit it may cause con densation and fog the glass This condensation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the ...

Страница 58: ...reas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These components should be replaced immediately 2 Remove the Cap and shine a flashlight down theVent Removeanybirdnests orotherforeign material 3 Checkforevidencesofexcessivecondensation such as water droplets forming in the inner liner and subsequently dripping out the joints Continuous con...

Страница 59: ...ny circumstances To Install the Fan 1 Remove the bottom louver door 2 Shut the power off by disconnecting 120 volt power cord at receptacle 3 Disconnect 2 wires at fan motor and ground wire at ground lug 4 Slide the fan in towards the front of the unit to remove from fireplace IMPORTANT These fans collect a lot of dust from within your home Ensure you maintain these fan motors on a regular basis b...

Страница 60: ...th a 17 mm 11 16 wrench Diagram 3 Lastly remove supply tube from valve with 19 mm 3 4 wrench Diagram 4 Note orientation of 90 Degree Brass fitting 11 Remove the twelve 12 Phillips head screws from the valve tray and then remove the valve traybyliftingupandout Replacewithnewvalve assembly and reverse steps If replacing valve only see following steps Diagram 7 2 Remove two 2 Phillips head screws on ...

Страница 61: ... Motor only 50 510 994 Rigid Pipe Adaptor Optional 51 790 011 Relief Frame Gasket 59 790 009 Relief Door Mounting Plate 60 W260260 Top Relief Frame Gasket 61 942 117 Top Relief Plate Frame 62 W260280 Top Relief Plate Gasket 63 290 021 Air Baffle Plate 64 904 732 Pressure Relief Bolt Each 65 946 556 Heat Wave Duct Kit Optional 89 946 004 Junction Box 90 946 000 Round Duct Adaptor 91 946 002 Round t...

Страница 62: ... Vent Gas Stove parts list 61 42 32 64 61 1 9 7 36 8 10 43 64 22 36 20 23 24 21 25 24 23 25 108 109 107 HEAT RELEASE DUCT KIT 62 51 59 60 61 63 64 65 50 93 97 98 99 100 102 90 96 95 93 92 91 94 89 HEAT WAVE DUCT KIT BRICK PANELS 33 34 35 ...

Страница 63: ...7 167 911 039 Pilot Hood 910 432 Pilot Tube w nuts 792 977 Conversion Kit LP 68 W840470 Pilot Assembly Gasket 79 791 535 Burner Assy NG LP 82 511 030 Burner Grate Assy 83 780 520 Rear Log Support Bracket 85 780 930 Log Set Complete Oak 85 780 932 Log Set Complete Birchwood 911 037 Flame Sensor 911 038 Spark Electrode 911 187 Remote Battery Box 911 127 Remote Battery Compartment Door 911 175 GTMF R...

Страница 64: ... Vent Gas Stove parts list Arch Surround and Safety Screen Assembly Part Description 1 792 038 Flush door frame 2 940 326 P Flush glass 936 155 Glass Gasket tadpole 3 792 920 Arch surround with safety screen 4 792 950 Black Double doors ...

Страница 65: ...Regency Excalibur P90E 11 Direct Vent Gas Stove 65 notes ...

Страница 66: ...Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory as...

Страница 67: ...drafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the a...

Страница 68: ...e the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a ...

Страница 69: ...elow in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchas...

Страница 70: ...70 Regency Excalibur P90E 11 Direct Vent Gas Stove warranty ...

Страница 71: ...Regency Excalibur P90E 11 Direct Vent Gas Stove 71 ...

Страница 72: ...______________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency and Excalibur are trademarks of FPI Fireplace Products International Ltd Copyright 2019 FPI Fireplace Products International Lt...

Отзывы: