background image

Regency CS1200  Freestanding Wood Stove

3

SAFETY LABEL

This is a copy of the label that accompanies each 

CS1200  Wood Stove

. We have printed a copy 

of the contents here for your review.

HOT WHILE IN OPERATION DO NOT TOUCH.  KEEP CHILDREN,

CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE

SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.

DO NOT REMOVE THIS LABEL

LISTED SPACE HEATER, SOLID FUEL TYPE,  ALSO 
SUITABLE FOR MOBILE HOME INSTALLATION 

MODEL:  

REGENCY  FREESTANDING STOVE -  CS1200

TESTED TO:  ULC S627-00 / UL 1482-2006 

 

 

    WN # 16599

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND  OPERATING INSTRUCTIONS.  CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT 
RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.  USE 150 MM (6 IN.) DIAMETER MINIMUM 24 MSG BLACK OR 25  MSG BLUED STEEL CONNECTOR WITH LISTED FACTORY-
BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY.  
SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.  DO NOT 
PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING.  DO NOT CONNECT THIS UNIT TO A CHIMNEY  FLUE SERVING ANOTHER APPLIANCE.

FLOOR 

PROTECTION*

K  405 mm / 16 in
L  150 mm / 6 in
M  150 mm / 6in

CERTIFIED TO COMPLY WITH  JULY 1990, 

PARTICULATE EMISSION STANDARDS.

UNITED STATES  ENVIRONMENTAL 

PROTECTION  AGENCY

MINIMUM ALCOVE CEILING HEIGHT: 2.15 M / 7 FT         MAXIMUM ALCOVE DEPTH 915 MM / 36 IN.    
MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING: 455 MM / 18"
THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED. OPERATE ONLY WITH FIREBRICKS IN PLACE.
FOR USE WITH SOLID WOOD FUEL ONLY.  USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION.  DO NOT OBSTRUCT COMBUSTION 
AIR OPENINGS.  OPERATE ONLY WITH FIREBRICKS IN PLACE.  OPERATE ONLY WITH DOOR CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY.  DO NOT USE GRATE 
OR ELEVATE FIRE.  BUILD WOOD FIRE DIRECTLY ON HEARTH.  DO NOT OVERFIRE - IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING.  INSPECT 
AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY.  UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY.  KEEP FURNISHINGS 
AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER.  REPLACE GLASS ONLY WITH NEOCERAM GLASS. COMBUSTIBLE FLOOR MUST BE PROTECTED BY 
NON-COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE 
MATERIAL.
OPTIONAL COMPONENT: FAN, ELECTRICAL RATING: VOLTS 115, 60 HZ, 2 AMPS, ASH DRAWER, SIDE SHIELD, ASHLIP
COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR
IN CANADA:  LISTED SECURITY MODEL DP, OR OLIVER MACLEOD PRO-VENT PV DOUBLE WALLED CONNECTOR WITH  LISTED CHIMNEY SYSTEM: SECURITY MODEL 
S2100, ICC EXCEL 2100 .
IN USA:   LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, SIMPSON DURA VENT MODEL DVL, 
GSW SUPER PIPE 6, METAL-FAB DOUBLE WALL.  CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL S2100 OR MODEL 
ASHT, SELKIRK MODEL SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODEL SC OR METAL-FAB TEMP/GUARD, AMERI-TEC HS,  ICC EXCEL 
2100 .  USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS. 

HAUTEUR MINIMALE DU PLAFOND DE L’ALCÔVE : 2,15 M / 7PI.   PROFONDEUR MAXIMALE DE L’ALCÔVE : 915 MM / 36 PO.
DÉGAGEMENT MINIMAL DU PLAFOND POUR UN CONNECTEUR HORIZONTAL : 455 MM / 18 PO.
L’ESPACE AU-DESSOUS DU POÊLE NE DOIT PAS ÊTRE OBSTRUÉ. UTILISER SEULEMENT AVEC LES BRIQUES RÉFRACTAIRES EN PLACE.
POUR UTILISATION AVEC BOIS SOLIDE SEULEMENT. L’UTILISATION D’AUTRES COMBUSTIBLES PEUT ENDOMMAGER LE POÊLE ET CRÉER UNE CONDITION 
DANGEREUSE. NE PAS OBSTRUER LES OUVERTURES D’AIR DE COMBUSTION. UTILISER SEULEMENT AVEC LA PORTE FERMÉE – OUVRIR LA PORTE DE CHARGEMENT 
POUR ALIMENTER LE FEU SEULEMENT. NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU. MONTER LE FEU DE BOIS DIRECTEMENT SUR L’ÂTRE. NE 
PAS SURCHAUFFER – SI LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR, VOUS SURCHAUFFEZ. INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA 
CHEMINÉE ET LE CONNECTEUR. EN CERTAINES CONDITIONS D’UTILISATION, UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT. GARDEZ LES MEUBLES 
ET AUTRES MATÉRIAUX COMBUSTIBLES ÉLOIGNÉS DU POÊLE. REMPLACEZ LA VITRE SEULEMENT PAR DU VERRE EN NEOCERAM. LE PLANCHER COMBUSTIBLE 
DOIT ÊTRE PROTÉGÉ PAR DES MATÉRIAUX NON COMBUSTIBLES DÉPASSANT DU DESSOUS, DU DEVANT ET DES CÔTÉS DU POÊLE, TEL QU’INDIQUÉ, OU JUSQU’AU 
MATÉRIAU COMBUSTIBLE LE PLUS PRÈS PERMIS.
COMPOSANTS EN OPTION : VENTILATEUR (846-515), ALIMENTATION ÉLECTRIQUE : 115 VOLTS, 60 HZ, 2 AMP., ASH DRAWER, SIDE SHIELD, ASHLIP
COMPOSANTS EXIGÉS POUR INSTALLATION DANS UNE MAISON MOBILE : KIT DE PRISE D’AIR EXTÉRIEUR ET L’UN DES CONNECTEURS DE CHEMINÉE À DOUBLE 
PAROI SUIVANTS :
AU CANADA : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, OU OLIVER MACLEOD PRO-VENT PV, AVEC SYSTÈME DE 
CHEMINÉE HOMOLOGUÉ : SECURITY MODÈLE S2100, ICC EXCEL 2100.
AUX ÉTATS-UNIS : CONNECTEURS DE CHEMINÉE HOMOLOGUÉS À DOUBLE PAROI : SECURITY MODÈLE DP, SELKIRK MODEL DS, OLIVER MACLEOD PRO VENT PV, 
SIMPSON DURA VENT MODÈLE DVL, GSW SUPER PIPE 6, METAL-FAB À DOUBLE PAROI. CONNECTÉ À L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS 
: SECURITY MODÈLE S2100 OU MODÈLE ASHT, SELKIRK MODÈLE SSII, OLIVER MACLEOD PRO JET 3103, SIMPSON DURA PLUS, GSW MODÈLE SC OU METAL-FAB 
TEMP/GUARD, AMERI-TECHS, ICC EXCEL 2100. UTILISER LES COMPOSANTS DE CHEMINÉE SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION.

MADE IN CANADA

 JAN 

  FEB 

 MAR 

 APR 

 MA

Y

 

 JUN 

 JUL

 

 AUG  

 SEPT 

 OCT 

 NOV 

 DEC

CAUTION / ATTENTION:

DA

TE OF MANUF

ACTURE

2010

2012

201

1

918-897 

MANUFACTURED BY: 

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.

 6988 

VENTURE 

ST.

 

DELTA, BC  V4G 1H4

duplicate serial number

366

366

  

 

* In Canada, fl oor pro-
tection must extend 18" 
to the front and 8" to 
each side of the stove.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

MEASURE 

FROM

SIDE SHIELDS/

BACK SHIELDS

FLUE

CENTRE-LINE

RESIDENTIAL INSTALLATION USING

 SINGLE WALL  CONNECTOR

SIDEWALL
BACKWALL
CORNER

A  13"  330mm
B  11"  280mm
C  8"    205mm

D  26-3/8"    669mm
E  18-1/2"    470mm
F  20-3/4"    527mm

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  MOBILE HOME

SIDEWALL
BACKWALL
CORNER

A  11"  330mm
B  7"    180mm
C  7"    180mm

D  24-1/2"    622mm
E  14.5"       368mm
F  19-3/4"    510mm

CHAUD LORS DE FONCTIONNEMENT.

NE PAS TOUCHER. GARDEZ LES ENFANTS, VÊTEMENTS ET MEUBLES AU LOIN. 

UN CONTACT AVEC LE PEAU PEUT OCCASIONER DES BRULURES.BRÛLURES 

CUTANÉES.

LIRE CETTE ÉTIQUETTE.

INSTALLER ET UTILISER SEULEMENT SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION DU FABRICANT.
CONTACTER LES RESPONSABLES DU BÂTIMENT OU DU SERVICE-INCENDIE DE VOTRE RÉGION POUR CONNAÎTRE LES RESTRICTIONS ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION. 
UTILISER UN CONNECTEUR D’UN DIAMÈTRE MINIMAL DE 150 MM (6 PO) 24 MSG EN ACIER NOIR OU 26 MSG EN ACIER BRONZÉ AVEC CHEMINÉE PRÉFABRIQUÉE HOMOLOGUÉE 
CONÇUE POUR UTILISATION AVEC COMBUSTIBLES SOLIDES OU UNE CHEMINÉE DE MAÇONNERIE.
VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT CONCERNANT LES PRÉCAUTIONS  EXIGÉES POUR INSTALLER UNE CHEMINÉE TRAVERSANT UN MUR OU 
PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE FAITES PAS TRAVERSER LE CONNECTEUR DE CHEMINÉE DANS UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES. NE RACCORDEZ PAS 
CE POÊLE À BOIS À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL.

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  RESIDENTIAL CLOSE CLEARANCE

SIDEWALL
BACKWALL
CORNER

A  11"  330mm
B  7"    180mm
C  7"    180mm

D  24-1/2"    622mm
E  14.5"       368mm
F  19-3/4"    510mm

INSTALLATION USING LISTED DOUBLE WALL 

CONNECTOR -  ALCOVE

SIDEWALL
BACKWALL

G  11"  330mm
H  7"    180mm

I  24-1/2"     622mm
J  14.1/2"    368mm

NOTE: 

 Regency units are constantly being 

improved.  Check the label on the unit and if 
there is a difference, the label on the unit is 
the correct one.

Содержание Alterra CS1200

Страница 1: ...Canada V4G 1H4 918 896a CS1200 Alterra Freestanding Wood Stove 11 08 10 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference ...

Страница 2: ...ALER in your area Keep those REGENCY FIRES burning SAFETY NOTES If this woodstove is not properly installed a house fire may result For your safety follow the installation instructions contact local building or fire officials about restrictions and installation inspection requirements in your area This appliance needs fresh air for safe operation and must be installed with adequate combustion air ...

Страница 3: ...ENT POUR ALIMENTER LE FEU SEULEMENT NE PAS UTILISER DE GRILLE À BÛCHES NI SURÉLEVER LE FEU MONTER LE FEU DE BOIS DIRECTEMENT SUR L ÂTRE NE PAS SURCHAUFFER SI LE POÊLE OU LE CONNECTEUR DE CHEMINÉE SE MET À ROUGIR VOUS SURCHAUFFEZ INSPECTEZ ET NETTOYEZ FRÉQUEMMENT LA CHEMINÉE ET LE CONNECTEUR EN CERTAINES CONDITIONS D UTILISATION UN DÉPÔT DE CRÉOSOTE PEUT SE FORMER RAPIDEMENT GARDEZ LES MEUBLES ET A...

Страница 4: ...ove Flue 12 Mobile Home Installation 13 Listed Components For Mobile Home Installation 14 Baffle and tube Installation 15 Brick Installation 15 Door Handle 15 Side panel Installation 16 Ash drawer option 17 Lower Surround reversal 18 Door reversal 19 Wood Storage 20 Ashlip Installation 20 Blower Fan installation 21 Fan Operation 21 Fan wiring 21 OPERATING INSTRUCTIONS Operating Instructions 22 Fir...

Страница 5: ...IMENSIONS 9 15 16 14 7 16 39 9 16 1105mm 17 1 8 436mm 26 3 4 680mm A A 21 3 4 552mm 37 13 16 961mm 19 1 16 485mm 250mm 367mm 17 1 8 436mm 27 1 8 689mm 9 15 16 250mm 7 5 16 186mm 17 1 8 435mm CL for outside air 6 flue collar Shown with optional blower installed ...

Страница 6: ... the door opening and 6 to the sides and rear of the unit Someareasmayrequirealargersizefloorprotector See your local inspector For outside air installation refer to Mobile Home section 8 When the floor protection is complete position the stovewiththefluecollarcenteredundertheinstalled chimney 9 In seismically active areas Regency recommends that your unit is secured to the floor by using the bolt...

Страница 7: ...r line CS1200 A B C D E F 13 11 8 26 3 8 18 1 2 20 3 4 Residential Close Clearance To be installed with required pipe components When the stove is installed as a close clearance residential unit a listed double wall connector is required from the stove collar to the ceiling level From Unit From Corner From Flue Center line CS1200 A B C D E F 11 7 7 24 1 2 14 5 19 3 4 Mobile Home Close Clearance To...

Страница 8: ...minimum 16 from the fuel door opening of the stove and minimum 6 or the rear clearance to combustibles whichever is smaller from the rear of the stove NOTE In Canada floor protection must extend 18 to the front and 8 to each side of the stove Minimum Alcove Clearance to Combustible Materials Unit From Back Shield Side Shields From Flue Center Line Min Width Min Hearth to Rear Wall CS1200 G H I J K...

Страница 9: ...t is recommended that no ceiling support member be cut for chimney and support box installation If it is necessary to cut them the members must be made structurally sound 2 Install radiant shield and support from above 3 Stacktheinsulatedpipeontoyourfinishsupport to a minimum height of 3 feet above the roof penetration or 2 feet above any point within 10 feet measured horizontally There must be at...

Страница 10: ... inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned beforethestoveisinstalledandoperated Whenconnect ing the stove through a combustible wall to a masonry chimney special methods are needed Ensure that an effective vapour barrier at the location where the chimney or other component penetrates to the exterior ...

Страница 11: ...clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick Chimney connector Fire clay liner Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minim...

Страница 12: ...00 16 0 17 0 18 5 20 0 24 0 21 0 26 5 9000 10000 16 5 17 5 19 0 20 5 24 5 22 0 27 0 NOTE No more than two offsets four elbows allowed Two 45o elbows equal one 90o elbow RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft See Table 1 1 At sea level minimum height is 12 straight 2 Addthefollowingverticalheighttocompensate for 45 deg elbow 1 ft 90 deg elbow 2 ft T 3 ft Each foot of horizonta...

Страница 13: ...h 8 a supply of fresh air has to be supplied to your unit Cut a minimum 4 inch diameter hole through your outside wall Use 4 duct pipe with a mesh grill to pipe fresh air into the back shield area Place your unit in position and secure it to the floor using two lag bolts 3 8 x 3 1 2 through the two holes inside the pedestal base It is important to maintain the structural integrity of the Mobile Ho...

Страница 14: ...BILE HOME INSTALLATION The Regency CS1200 is approved for installation in a Mobile Home if one of the following pipe systems is used U S Installation METALBESTOS SSII Qty Part Description 1 6DS VK Connector Kit 1 6TMH Shield Support 1 6TAF 6 Flashing 1 6T 36 Chimney Length 1 6T 18 Chimney Length 1 6T CT Rain Cap PRO JET 3103 Qty Part Description 1 PV06 TK Connector 1 CSB Shield Support 1 RRS Radia...

Страница 15: ... and then slide it back over the rear air tube 3 Tilt the left baffle brick up on top of the side channel and it will leave enough room to position the right baffle brick in the same manner as Step 1 above Then reposition the left baffle brick flat on the air tube The door handle can be removed and stored on a hanger located on the inside left in the wood storage area 4 Important push both baffle ...

Страница 16: ...t to the unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty One set of side panels needs to be installed on the stove When installing stainless steel side panels follow the handling and cleaning instructions below 1 Bend the metal tab located in the top front corner of the side panels to a 45 angle with a pair of pliers...

Страница 17: ...al in operating instructions 1 Open the main top door and the center door on the front of the unit 3 Remove the ash dump cover plates one inside the firebox and one on the underside of the firebox access the lower plate through the center door it is directly below the upper ash dump plate by removing the two nuts and bolts holding the 2 plates together from underneath the stove Ash Dump Plates Ash...

Страница 18: ...ts 2 Remove the latch on the left side of the unit by removing 2 bolts 3 Rotate the latch 180 and reinstall on the right side 4 Rotate both hinge 180 and reinstall hinge on left side 5 Remove and rotate both the male part of the latch 180 located on the inside of the lower surround door Install the latch on the opposite side of the door Door latch male portion 6 Reinstall the door do not rotate on...

Страница 19: ...to prevent air leakage 3 Remove the 2 bolts securing the door catch assembly to the unit 6 Remove the glass from the door and flip it around 180 so the painted strip is at the bottom of the door 7 Flip the handle around 180 and reattach to the door with 2 botls 4 Flip the door hinge 180 install on the left side of the unit with 2 bolts 5 Reattach the door catch assembly on the right side with 2 bo...

Страница 20: ...er within pedestal Note Please refer to local codes B365 NFPA211 and your local jurisdiction Store wood behind door opening 1 Open lower surround door 2 Ashlip to be positioned just below the ashdrawer if installed 3 Manoeuvre ashlip into position on an angle the tabs on the ashlip rest behind side walls on unit see diagrams below Tabs on ashlip Final install of Ashlip Ashlip to be positioned here...

Страница 21: ...e is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly groundedthree prongreceptacle Donotcutorremove the grounding prong from this plug NOTE This appliance when installed must be electrically grounded in accord ance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or ...

Страница 22: ...flamemaybedrawnout of the fireplace stove opening creat ing risks from both fire and smoke DRAFT CONTROL Both the primary and air wash drafts are controlled by the control rod located on the left side of the unit when facing the unit To increase your draft pull open and to decrease push closed All units have a secondary draft system that continually allows combustion air to the induction ports at ...

Страница 23: ...of the stove when the stove is cold Remove the plug by lifting on the handle using the tool provided Push the ashes down the hole into the ash drawer the large pieces can be left in the firebox and burned during the next fire or removed through the door opening 2 Always leave 1 2 to 1 inch of ash in the bottom of the firebox This helps in easier starting and a more uniform burn of your fire Replac...

Страница 24: ... another appliance 10 Do not use grates or andirons or other methods for supporting fuel Burn directly on the bricks 11 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire 12 Do not connect your unit to any air distribution duct 13 Your woodstove must burn dry seasoned standard firewood only The use of cut lumber plywood mill ends coal charco...

Страница 25: ...ainer Use caution when removing broken glass to avoid injury When placing the replacement glass in the door make sure that the glassgasketingwillproperlysealyourunit Replace the retainer it should rest on the gasket not the glass and tighten securely with a glass clips and screws Do not wrench down on the glass as this may cause breakage Do not use substitute materials If your glass does break do ...

Страница 26: ...ld Black Set 076 927 Side Shield Stainless Set 7 156 519 Door Catch Assembly 8 076 516 Heat Shield 9 156 523 Door Hinge Assembly 10 942 110 Ash drawer plug 11 076 911 Ash Drawer Assembly 12 076 004 Fan Opening Cover 13 076 010 Back Shield 14 074 954 Air tube 15 033 953 Air tube 16 073 955 Baffle set 17 076 913 Ashlip Part Description Firebox Assembly 940 366 P Neoceram Glass 918 896 Manual Not ava...

Страница 27: ...tom 3 222 036 Sensor Mount 4 200 227 Fan Bracket Right Hand 5 200 228 Fan Bracket Left Hand 6 200 229 Fan Housing Back 7 910 157 P Fan 8 910 142 Thermodisc Part Description 1 076 960 Firebrick Set RED LOW WHITE COMMON CONNECTION DIAGRAM BLACK HIGH 115V 60HZ 1 1A J250 150 O44003 T P 3000 RPM JAKEL INC DATE T P L B 5 6 2 3 4 7 8 1 FAN ASSEMBLY FIRE BRICK ...

Страница 28: ...28 Regency CS1200 Freestanding Wood Stove NOTES ...

Страница 29: ...Regency CS1200 Freestanding Wood Stove 29 NOTES ...

Страница 30: ...30 Regency CS1200 Freestanding Wood Stove NOTES ...

Страница 31: ... or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or pa...

Страница 32: ..._________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers ...

Отзывы: