Regency CI1150 Wood Cast Insert
|
21
maintenance
Ground
Fan
Fan
Ground
Green
Neutral
Live
White
Fan
Switch
Manual/
Auto
Switch
White
White
High
(Black)
Low
(Red)
Black
Fan Thermodisc
(normally open)
120V AC
60 Hz
Black
Fan Wiring Diagram
HI
OFF
LOW
AUTO
MANUAL
Cord Reversal
The fan cord comes out from the left hand side of the unit. if it is necessary
to have the cord coming from the right side - follow these steps:
1) Remove the lower surround faceplate section by removing 2 bolts.
2) Feed the cord along the bottom of the inside of the casting as shown below.
Fan Operation
The fan is to be operated only with the draft control rod pulled out at least
1/2" from the fully closed position. The fan is not to be operated when the
draft control rod is in the closed position (pushed in). The fully closed posi-
tion is the low burn setting.
The fan must not be turned on until a fire has been burning for at least 30
minutes. Also note it is recommended that the fan be turned off before each
fuel loading and again wait for 30 minutes before the fan is turned on again.
This is to allow the stove to reach its optimum temperature.
To operate fan automatically, push switch on the right side of fan housing to
"Auto" and second switch, on the left to either "High" or "Low" for fan speed.
The automatic temperature sensor will engage the blower when the unit is at
temperature and will shut off the blower once the fire has gone out and the
unit has cooled to below a useful heat output range.
To manually operate the fan system, push the first switch to "Man" and second
switch to either "high" or "Low". This will bypass the sensing device and allow
full control of the fan. Switching from "Auto" to "Manual" or "High" to "Low"
may be done at any time.
Содержание Alterra CI1150
Страница 37: ...Regency CI1150 Wood Cast Insert 37 ...
Страница 38: ...38 Regency CI1150 Wood Cast Insert notes ...
Страница 39: ...Regency CI1150 Wood Cast Insert 39 ...