background image

4

 | 

Regency CI1150 Wood Cast Insert

safety decal

This is a copy of the label that accompanies each C

I1150 

Wood Insert

. We have printed a copy of the contents here 

for your review.

NOTE: 

 Regency units are constantly being improved.  Check 

the label on the unit and if there is a difference, the label on 

the unit is the correct one.

Copy of the CI1150 Safety Decal

Part #:  920-161

Colour:   Black on grey, except for selected items which are printed red.

Size: 

File is at 100%.   4" W x 10.7" H (excluding tear off)

Start serial sequence at 534000001

Oct. 08/19:  Created decal

LISTED FACTORY BUILT FIREPLACE INSERT

CERTIFIED FOR USE IN CANADA AND U.S.A.

MODEL: 

CI1150

TESTED TO:

ULC S628-M93  / UL 1482-2011 (R2015)

   

  

  

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE

534

COMPONENTS REQUIRED FOR INSTALLATION: 5.5" (140mm) or  6" (152mm)STAINLESS STEEL 

LINER LISTED CHIMNEY LINER.  

OPTIONAL COMPONENT: FAN PART#172-917, ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS

DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

DO NOT REMOVE BRICKS OR MORTAR IN MASONRY FIREPLACE.  FOR USE WITH SOLID WOOD FUEL 

ONLY.  DO NOT USE GRATE OR ELEVATE FIRE.  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE 

SERVING ANOTHER APPLIANCE. BUILD WOOD FIRE DIRECTLY ON HEARTH. OPERATE WITH FEED 

DOOR CLOSED, OPEN TO FEED FIRE ONLY.  REPLACE GLASS ONLY WITH CERAMIC GLASS (5MM).  

INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE 

BUILD-UP MAY OCCUR RAPIDLY.  DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.

CAUTION: MOVING PARTS MAY CAUSE INJURY. DO NOT OPERATE UNIT WITH A

REMOVED PART OR PARTS.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS 

(MEASURED FROM SIDE/TOP OF DOOR)

COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 

16 IN / 405MM TO  FRONT AND (G) 8IN / 205MM TO SIDES FROM FUEL DOOR. IN CANADA MUST 

EXTEND 18” TO FRONT.

THERMAL INSULATION WITH A R VALUE = 1.4 AT A DISTANCE OF 18" FROM FRONT OF DOOR 

OPENING FOR CANADA AND 16" FOR USA. IF UNIT RAISED 4.5" FROM FLOOR, NO THERMAL INSU-

LATION IS REQUIRED.

MANUFACTURED BY/ 
FABRIQUÉ PAR :
FPI FIREPLACE PRODUCTS 
INTERNATIONAL LTD.
6988 VENTURE ST.
DELTA, BC  V4G 1H4

HOT WHILE IN OPERATION

DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND 

FURNITURE AWAY.

CONTACT MAY CAUSE SKIN BURNS. 

READ ABOVE INSTRUCTIONS.

APPAREIL CHAUD LORSQU’IL FONCTIONNE. 

NE PAS TOUCHER. GARDER À DISTANCE DES ENFANTS, DES 

VÊTEMENTS ET DU MOBILIER.  

TOUT CONTACT PEUT CAUSER DES BRÛLURES.   

LIRE LES INSTRUCTIONS CI-DESSUS.

ATTENTION / DANGER

ADJACENT SIDEWALL  A)  15 in / 380 mm

MANTEL 

B)  20 in / 510 mm

TOP FACING 

C)  14 in / 355 mm

SIDE FACING 

D)  7 3/8 in / 187 mm

INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S

INSTALLATION AND OPERATING INSTRUCTIONS.  INSTALL AND USE ONLY

IN MASONRY FIREPLACE OR FACTORY BUILT FIREPLACE.

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND

INSTALLATION INSPECTION IN YOUR AREA.

 

    JAN

    FEB

 

  MAR

 

  APR

 

  M

AY

 

 JUN

 

 JUL

 

AUG

 

SEPT

 

OCT

 

NOV 

 

DEC

2020

2021

2022

2023

(Duplicate Serial #)

DA

TE OF MANUF

ACTURE / DA

TE DE F

ABRICA

TION

MADE

 IN

 CANADA

 / 

FAIT

 AU

 CANADA

A

D

B

C

MUR LA

TÉRAL

ADJACENT

PIÈCES OBLIGATOIRES POUR L’INSTALLATION : GAINE DE CHEMINÉE HOMOLOGUÉE EN ACIER 

INOXYDABLE DE 5,5 PO (140mm) ou  6 PO (152mm).  

PIÈCE EN OPTION : VENTILATEUR PIÈCE N

O

172-917

CARACTÉRISTIQUES ÉLECTRIQUES : 115 VOLTS, 60 HZ, 0,6 AMPS.

DANGER : RISQUE D’ÉLECTROCUTION. DÉBRANCHER LE COURANT AVANT DE PROCÉDER À L’EN-

TRETIEN DE L’APPAREIL.

NE PAS RETIRER LES BRIQUES OU LE MORTIER DU FOYER EN MAÇONNERIE. À UTILISER AVEC 

UN COMBUSTIBLE SOLIDE EN BOIS SEULEMENT. NE PAS UTILISER DE GRILLE NI SURÉLEVER LE 

FEU. NE PAS CONNECTER CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE 

APPAREIL. FAIRE UN FEU DE BOIS DIRECTEMENT SUR L’ÂTRE.  FAIRE FONCTIONNER L’APPAREIL 

AVEC LA PORTE DE CHARGEMENT FERMÉE, L’OUVRIR SEULEMENT POUR ALIMENTER LE FEU. 

REMPLACER LA VITRE SEULEMENT AVEC UNE VITRE EN CÉRAMIQUE (5MM). FAIRE INSPECTER 

ET RAMONER LA CHEMINÉE À INTERVALLES RÉGULIERS. ACCUMULATION RAPIDE DE CRÉOSOTE  

DANS CERTAINES CONDITIONS. NE PAS SURCHAUFFER : SI L’ENCASTRABLE EST ROUGEOYANT, 

L’APPAREIL SURCHAUFFE.

ATTENTION : LES PIÈCES AMOVIBLES PEUVENT ENTRAÎNER DES BLESSURES. NE PAS FAIRE 

FONCTIONNER L’APPAREIL SI UNE OU PLUSIEURS PIÈCES ONT ÉTÉ ENLEVÉES.

DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES

(MESURES PRISES DEPUIS LE CÔTÉ / HAUT DE LA PORTE)

LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIAU NON COMBUSTIBLE 

S’ÉTENDANT SUR (E) 16 PO / 405MM À L’AVANT ET SUR (G) 8 PO / 205MM ENTRE LES CÔTÉS ET LA 

PORTE DE CHARGEMENT DU COMBUSTIBLE. PROLONGEMENT SUR 18 PO À L’AVANT AU CANADA.

ISOLATION THERMIQUE AVEC UNE VALEUR R = 1,4 À UNE DISTANCE DE 18 PO DEPUIS L’AVANT DE 

L’OUVERTURE DE LA PORTE AU CANADA  ET 16 PO AUX ÉTATS-UNIS. SI L’APPAREIL EST SURÉLEVÉ 

À 4,5 PO DU SOL, AUCUNE ISOLATION THERMIQUE N’EST REQUISE.

MUR LATÉRAL ADJACENT          A) 15 po / 380 mm

MANTEAU 

 

  B) 20 po / 510 mm

PAREMENT SUPÉRIEUR          C) 14 po / 355 mm

PAREMENT LATÉRAL  

  D) 7 3/8 po / 187 mm

920-161

534

CERTIFIÉ CONFORME AUX NORMES 2020 DU U.S. ENVIRONMENTAL PROTECTION AGENCY EN MATIÈRE 
D'ÉMISSION DE PARTICULES DE BOIS EN UTILISANT LE BOIS DE CORDE. HOMOLOGUÉ AVEC LA 
ASTM E3053. MODÈLE REGENCY CI1150 –1.7 G /H. CET APPAREIL DE CHAUFFAGE AU BOIS DOIT ÊTRE 
INSPECTÉ PÉRIODIQUEMENT ET RÉPARÉ POUR FONCTIONNER CORRECTEMENT. CONSULTER LE 
MANUEL D’INSTALLATION POUR PLUS D’INFORMATION. LA RÉGLEMENTATION FÉDÉRALE INTERDIT 
DE FAIRE FONCTIONNER UN TEL APPAREIL SI LES CONSIGNES D’UTILISATION CONTENUES DANS LE 
PRÉSENT MANUEL NE SONT PAS RESPECTÉES.

0219WN027S

D’INSTALLATION ET D’UTILISATION DU FABRICANT. À INSTALLER ET À UTILISER UNIQUEMENT DANS 

UN FOYER EN MAÇONNERIE OU UN FOYER PRÉFABRIQUÉ.

CONTACTEZ LES AUTORITÉS LOCALES EN BÂTIMENT OU INCENDIE POUR CONNAÎTRE LES  RE-

STRICTIONS D’INSTALLATION ET LES RÈGLES D’INSPECTION DANS VOTRE RÉGION.

U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH 2020 PARTICULATE EMIS-
SION STANDARDS USING CORD WOOD.”  TESTED TO ASTM E3053.  MODEL REGENCY CI1150 – 1.7G /HR. 
THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. CONSULT 
THE OWNER’S MANUAL FOR FURTHER INFORMATION. IT IS AGAINST FEDERAL REGULATIONS TO 
OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN 
THE OWNER’S MANUAL.

Содержание Alterra CI1150

Страница 1: ...a V4G 1H4 920 160 CI1150 Alterra Wood Insert 01 15 20 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference Project No 0219WN027S ...

Страница 2: ...thin the building envelope It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual This heater is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods DO NOT BURN Treated wood Lawn cli...

Страница 3: ... 17 Stainless Steel Smoke Deflector Installation 18 Operating Instructions Seasoned Wood 19 Operating Instructions 20 Draft Control 20 First Fire 20 Fan Operation 21 Cord reversal 21 Maintenance Ash Disposal 22 Safety Guidelines and Warnings 22 Maintenance 23 Creosote 23 Wood Storage 23 Door Gasket 24 Glass Cleaning 24 Door Removal 24 Glass Replacement 24 Handle Replacement 25 Door Catch Adjustmen...

Страница 4: ...UR LATÉRAL ADJACENT PIÈCES OBLIGATOIRES POUR L INSTALLATION GAINE DE CHEMINÉE HOMOLOGUÉE EN ACIER INOXYDABLE DE 5 5 PO 140mm ou 6 PO 152mm PIÈCE EN OPTION VENTILATEUR PIÈCE NO 172 917 CARACTÉRISTIQUES ÉLECTRIQUES 115 VOLTS 60 HZ 0 6 AMPS DANGER RISQUE D ÉLECTROCUTION DÉBRANCHER LE COURANT AVANT DE PROCÉDER À L EN TRETIEN DE L APPAREIL NE PAS RETIRER LES BRIQUES OU LE MORTIER DU FOYER EN MAÇONNERIE...

Страница 5: ... of faceplate 6 152mm Diameter STANDARD FLUE ADAPTOR 172 942 17 5 16 440mm 14 1 8 from flue centerline to rear of faceplate 6 152mm Diameter OFFSET FLUE ADAPTOR 172 946 NOTE Beforeassembling your Insert use these dimensions to ensure ap propriate clearances will be met refer to Masonry and Factory Built Fire placeClearancessection Offset Flue Adapter Standard Flue Adapter 15 1 8 384 mm 15 1 8 384 ...

Страница 6: ...gency CI1150 Wood Cast Insert dimensions Optional Backing Plate Dimensions 40 1016mm 40 1016mm 37 940mm 37 914mm 29 1 2 749mm 27 686mm 26 660mm 23 5 8 600mm CI1150 Standard CI1150 Custom Minimum Dimensions ...

Страница 7: ... F per UL 1777 U S or ULC S635 Canada The liner must be securely attached to the insert flue collar and the chimney top 5 Means must be provided to prevent room air passage to the chimney cavity of the fireplace This may be accomplished by sealing the damper area around the chimney liner or sealing the fireplace front Regency Inserts are constructed with the highest qualitymaterialsandassembledund...

Страница 8: ...at your floor protection and hearth will meet the standards for clearance to combustibles Your hearth extension must be made from a non combustible material Extending 16 for US and 18 for Canada measured from the fuel loading door Unit CI1150 Adjacent Side Wall to side A Mantel to top B Top Facing to top C Side Facing to side D Minimum Hearth Extension E Minimum Hearth Side Extension F From Top of...

Страница 9: ...Diagram 2 Alignment of the flue adaptor can be critical during the install it is recommended that the flex liner be left as compressed as possible Before inserting the unit the adaptor should hang when level slightly above the required height 3 Install the unit by first setting the rear of the unit into the fireplace See Diagram 3 En sure that the unit is centered in the existing fireplace and lin...

Страница 10: ...pproximately the alignment of the flue liner with the position of the smoke outlet hole on the insert to check for possible offset If an offset is required use the appropriate offset adaptor in your installation 6 Oncetheaboveitemshavebeenchecked slide your insert into position after first positioning and securing the flue liner to the offset adaptor Attachtherodtotheadaptorandslidetheadap tor ont...

Страница 11: ...wn below Line up the left side casting bracket with the left side bracket on the unit 5 Secure the left cast surround with the two bolts removed in Step 3 4 Install fan controls into left surround with 2 screws as shown below Note Left side faceplate when facing unit will have a notch on the side as shown below The extension cord should also be brought out to the side prior to installation 2 Insta...

Страница 12: ...ight so it is out of the way Note If the fan power cord needs to be re routed to the right side of the unit go to step 16 before installing the lower cast surround piece 13 Line up the brackets on the lower cast surround piece with the lower holes in the bracket on the unit Replace the two 2 bolts removed in step 11 14 Before tightening the bolts adjust the position of the lower cast sur round unt...

Страница 13: ... the right side of the unit if necessary Before installing the lower cast surround run the cord between the left cast surround and the unit Then run the cord along the lower part of the lower cast surround and out in between the right cast and the unit 17 With the cord re routed follow steps 13 15 to complete the installa tion ...

Страница 14: ...OG EH IDFLQJ WKH IURQW RI WKH EDFN LQJ SODWH Install 2 clips to the back of the top cast faceplate with hex bolts If the unit is already installed remove the top cast faceplate from the unit if access is too difficult see Cast Faceplate Installation in the owners manual for instructions 6OLGH WKH EDFNLQJ SODWH RYHU WKH FOLSV RQ WKH EDFN RI WKH FDVW WRS 7KHUH DUH QRWFKHV LQ WKH EDFNLQJ SODWH ZKHUH ...

Страница 15: ...age 3 Remove the 2 bolts securing the door catch assembly to the unit 6 Remove the glass from the door and flip it around 180 so the painted strip is at the bottom of the door 7 Flip the handle around 180 and reattach to the door with 2 bolts 4 Flip the door hinge 180 install on the left side of the unit with 2 bolts 5 Reattach the door catch assembly on the right side with 2 bolts from step 3 Doo...

Страница 16: ...positions Do not use a grate LyTherm sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks Fire bricks Size 1 4 1 4 x 7 2 4 1 2 x 7 3 9 x 4 1 2 4 9 x 2 5 3 1 2 x 4 1 2 6 4 1 4 x 8 7 3 1 2 x 2 1 4 1 4 6 5 3 7 2 ITEM NO PART NUMBER QTY DESCRIPTION 7 RD 14287 2 3 500 x2 2500 BRICK 6 RD 14286 2 4 250 x 8 000 x 30 DEG BRICK 5...

Страница 17: ...easier to remove the air tubes by removing both the bottom right base brick and right side wall brick 5 Install left and right baffle brackets installation of left baffle bracket shown below Baffle Installation 4 Install the right and left side baffles right side baffle shown below 3 Install the center baffle 6 Secure the baffles into position by lifting up on the brick slightly so that the lockin...

Страница 18: ...en off both bolts and slide deflector downward push deflector to the back wall of the unit and manoeuver out Install new deflector and hand tighten bolts Ensure positive location of the deflector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a cutaway view from the back o...

Страница 19: ...es Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicat...

Страница 20: ...rate level and avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed Always build up the fire slowly 4 For the first few days the stove will give off an odour from the paint This is to be expected as thehightemperaturepaintbecomesseasoned Windows and or doors should be left open to provide adequate ventilation whil...

Страница 21: ...position pushed in The fully closed posi tion is the low burn setting The fan must not be turned on until a fire has been burning for at least 30 minutes Also note it is recommended that the fan be turned off before each fuel loading and again wait for 30 minutes before the fan is turned on again This is to allow the stove to reach its optimum temperature To operate fan automatically push switch o...

Страница 22: ...e draft control Over firing can cause extensive damage to your stove including warping and premature steel corrosion Over firing will void your warranty 6 Do not permit creosote or soot build up in the chimney system Check and clean chimney at regular intervals Failure to do so can result in a serious chimney fire 7 YourRegencystovecanbeveryhot Youmaybe seriously burned if you touch the stove whil...

Страница 23: ...apours which might otherwise be deposited within the system 3 Only burn seasoned wood Avoid burning kiln dried wet or green wood Seasoned wood has been dried at least one year Wood Storage Store wood under cover such as in a shed or cov ered with a tarp plastic tar paper sheets of scrap plywood etc asuncoveredwoodcanabsorbwater from rain or snow delaying the seasoning process Maintenance It is ver...

Страница 24: ...nd check the clearance to the Right Hand Cast Side Iftightorrubbing loosenthe 7 16nutsandadjusttheclearance and then re tighten Glass Replacement Allow the stove to cool before removing or replacing glass Remove the door from the stove and remove the glass retainer Use caution when removing broken glass to avoid injury When placing the replacement glass in the door make sure that the glass gasketi...

Страница 25: ...cer washer shown in the diagram below will allow the catch to be moved closer to the door frame causing a tighter seal Remove and replace the nuts washer and spacer as shown TO REMOVE THE FAN 1 See next page Maintenance The sealed bearings are lubricated there is no need to lubricate them further Extra lubricant will cause more lint and dust buildup causing the bearings to prematurely fail Regular...

Страница 26: ...crews with 3 16 Allen Key to remove lower cast sur round set aside on a soft surface 4 Lift fan housing up off pins on floor of unit 5 Remove fan from unit 9 To install fan reverse Steps 8 1 6 Remove 3 screws to remove fan heat shield 7 Slide back the protect shearth on the wiring disconnect the black red and white wires 8 Disconnect the ground wire located on the left side of the fan housing Pins...

Страница 27: ...ips using a hammer tap vise grips from right to left until air tube is released from grip Remove 4 Remove top left and right metal retainers followed by the fragile three piece C Cast Baffles then remove the remaining 2 tubes Secondary Air Tubes 5 To reinstall or replace first slide left side of tube into hole on left side air channel Align tab on right side air channel with notch on right hand en...

Страница 28: ...s 1 Remove 2 front secondary air tubes vermiculite baffles see manual for details 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOTE ENSURE BAFFLE IS PUSHED UP AS FAR AS POSSIBLE TIGHT TO TOP OF FIREBOX Vertical Deflector Remove 2 front air tubes Slide right down to remove Reverse to replace ...

Страница 29: ...g The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti seize lube ie never seize Check glass for cracks Replace if required Clean blower motor Disconnect power supply Remove and clean blower DO NOT LUBRICATE Inspect and clean chimney Annual professio...

Страница 30: ...ry Air Cover Plate 12 075 063F Andiron each 13 910 157 P Fan Motor 21 19 20 1 2 2 3 5 5 6 8 7 18 17 16 15 14 11 10 9 12 13 4 Part Description 14 075 064 Andiron Bracket Each 15 156 004 Door Hinge 16 156 035 Glass Gasket Frame 17 940 366 P Neoceram Glass 18 156 513 Door Assembly Metallic Black no glass 846 570 Med Density Door Gasket Kit 19 156 515 P Door Aligner Assembly 20 156 241 Cast Handle 21 ...

Страница 31: ...0 x 8 000 x 30 DEG BRICK 5 802 147 1 3 500 x 4 500 BRICK 4 802 152 2 2 000 x 9 000 BRICK 3 902 111 3 9 000 x 4 500 STANDARD BRICK 2 RD 14289 2 4 500 x 7 000 BRICK 1 RD 14288 2 4 250 x 7 000 BRICK Brick Panels 172 960 CI1150 Brick Kit Complete Fire bricks Size 1 4 1 4 x 7 2 4 1 2 x 7 3 9 x 4 1 2 4 9 x 2 5 3 1 2 x 4 1 2 6 4 1 4 x 8 7 3 1 2 x 2 1 4 ...

Страница 32: ...st Insert parts list Cast Faceplate Part Description 156 951 Metallic Black Faceplate CI1150 1 Top Surround 2 Left Side Surround 3 Right Side Surround 4 Bottom Surround Not available as a replacement part CI1150 Bottom Surround ...

Страница 33: ...ing 1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI...

Страница 34: ...orrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs kiln dried wood lack of regular maint...

Страница 35: ...s so the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain all warranty and service In the event the authorized selling dealer is unable to pro...

Страница 36: ...der for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in...

Страница 37: ...Regency CI1150 Wood Cast Insert 37 ...

Страница 38: ...38 Regency CI1150 Wood Cast Insert notes ...

Страница 39: ...Regency CI1150 Wood Cast Insert 39 ...

Страница 40: ..._________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Printed in Canada Regency Alterra are trademarks of FPI Fireplace Products International Ltd Copyright 2020 FPI Fireplace Products International Ltd A...

Отзывы: