Regency CI1150 Wood Cast Insert
|
9
installation
Installing Your Insert
SAFETY NOTE:
The insert is very heavy and
will require two or three people to move it into
position. The insert can be made a little lighter
by removing the cast iron door by opening it and
lifting it off its hinges. Be sure to protect your
hearth extension with a heavy blanket or carpet
scrap during the installation.
NOTE:
You will be required to purchase either
the standard or offset 6" diameter (152mm)
flue adaptor that is best suited for the specific
installation.
List of Tools needed;
- Pull Rod (included with insert)
- 1/2” socket / ratchet
- 3/8 open face wrench
1. Install flex liner into existing chimney as per
liner manufacturer’s specifications. See
Diagram 1.
Pull Rod
10. Re-install the door if removed prior to installa-
tion.
NOTE: The pull rod should not be thrown
away. It should be kept if the stove
is ever needed to be removed from
the fireplace.
Flex Liner
Pull Rod In Place
Pull Rod
Diagram 1
Diagram 2
Diagram 3
Diagram 4
Diagram 5
Diagram 6
Flue Adaptor
Diagram 7
2. Install the required flue adaptor onto the end
of the flex liner. Secure the adaptor using 3
screws - 1 on the front (not shown in image),
left, and right side. See Diagram 2.
Alignment of the flue adaptor can be critical
during the install, it is recommended that the
flex liner be left as compressed as possible.
Before inserting the unit the adaptor should
hang, when level, slightly above the required
height.
3. Install the unit by first setting the rear of the
unit into the fireplace. See Diagram 3. En
-
sure that the unit is centered in the existing
fireplace and lined up with the flue adaptor.
4. Slide the unit back until the flue adaptor is
slightly engaged.
5. At this point it is recommended to level the
unit and ensure that the leveling bolts rest on
the surface of the fireplace. This will keep the
adaptor from binding as the unit is slid into
position.
6. Insert the provided pull rod through the hole
in the top center of the unit. Secure the
threaded end into the flue adaptor as shown
in Diagram 4. While sliding the unit into place
pull on the rod to ensure that the flue adaptor
is properly engaged. See Diagram 5.
7. Ensure that the unit is still level.
8. To complete the installation and to ensure a
secure fit and connection of the flue adaptor
to the insert, it is essential that the two bolts,
flat washers and lock washers (supplied with
packaged manual) be installed and tightened
using a 1/2" socket as shown in Diagram 6.
This prevents the possibility of creosote drip
and exhaust gas leakage.
9. Remove the pull rod from the top center of the
fireplace. See Diagram 7.