maintenance
REMOVING THE VALVE ASSEMBLY
1. Shut off gas.
2. Disconnect power source to the stove.
3. Remove front door by opening it up, then slide the access panel to the left
and pull out.
a) Front panel on pedestal model (Diagram 1)
b) Panel from bottom of leg shield (Diagram 2)
Diagram 2
Diagram 1
Access Panel
Cover Plate
Valve Cover
Plate
Note: Access panel has to be loosened only to be taken out.
Slide left and out to remove and through cover plate opening
(see picture).
4. Remove valve cover plate by removing two (2) Phillips head screws.
5. Disconnect wire harness from receiver/battery backup as shown below.
6. Remove cover plate by first removing four (4) Phillips head screws.