CLASSIC™ C34E-11 Direct Vent Freestanding Gas Stove
|
43
maintenance
GLASS GASKET
If the glass gasket requires replacement use a glass
gasket 1/8 x 1 Window (Part # 936-240 x 4 feet).
CAUTION: Wear gloves when removing
damaged or broken glass.
WARNING: Do not operate the
appliance with the glass panels
removed, cracked or broken.
Replacement of the glass panels
should be done by a licensed or
qualified service person.
GLASS DOOR
Your Regency
®
fireplace is supplied with high
temperature 5mm Ceramic glass. If your glass
requires cleaning, we recommend using an approved
glass cleaner available at all authorized dealers. Do
not use abrasive materials.
CAUTION & WARNINGS:
* Do not clean when the glass is hot.
* The use of substitute glass will void all product
warranties.
* Care must be taken to avoid breakage of the
glass.
* Do not strike or abuse the glass.
* Do not operate this fireplace without the glass
front or with a cracked or broken glass front.
* Wear gloves when removing damaged or broken
glass.
* Replacement of the glass panel(s) should be
done by a licensed or qualified service person.
GLASS REPLACEMENT
In the event that you break your glass by impact,
purchase your replacement from an authorized
Regency
®
dealer only.
Replacement neoceramic glass (Part # 490-548)
is shipped with gasket.
GENERAL VENT
MAINTENANCE
Conduct an inspection of the venting system semi-
annually. Recommended areas to inspect as follows:
1.
Check the Venting System for corrosion in areas
that are exposed to the elements. These will
appear as rust spots or streaks, and in extreme
cases, holes. These components should be
replaced immediately.
2.
Remove the Cap, and shine a flashlight down
the Vent. Remove any bird nests, or other foreign
material.
3.
Check for evidences of excessive condensation,
such as water droplets forming in the inner
liner, and subsequently dripping out the joints,
Continuous condensation can cause corrosion
of caps, pipe, and fittings. It may be caused
by having excessive lateral runs, too many
elbows, and exterior portions of the system
being exposed to cold weather.
4.
Inspect joints, to verify that no pipe sections or
fittings have been disturbed, and consequently
loosened. Also check mechanical supports such
as Wall Straps, or plumbers' tape for rigidity.