Unit Dimensions
*
The fireplace bottom standoff is required if the fireplace is installed on a combustible floor surface or on a combustible floor structure or on
a combustible raised platform. See section "INSTALLATION: Flooring Requirements" for all the details regarding the requirements to use the
fireplace bottom standoff.
* The chase cavity requires four (4) ventilation grills which are included with the unit. Each grill requires a minimum of 28.5 square inches of open area.
Two (2) at ceiling level and two (2) at floor level. Grills must be installed and are supplied with the unit.
Optional: If installing grills other than the ones supplied, you must adhere to the minimum open area. For example, you can install two (2) large
grills , one at ceiling level and one at floor level, but each grill must be 57 square inches of open area.
** Shown with Anchor Plate.
The anchor plate height will vary depending on the specific chimney manufacturer. See specific chimney manufactured product catalogue for
complete details.
ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS.
4"
OUTSIDE
AIR
31 14 "
VIEWING
23 34 "
VIEWING
41"
37 38 "
DOOR OPENING
CF780 Wood Fireplace
|
7
installation