installer's information
Installation Checklist
1. Locate appliance. Refer to the following sections:
a) Locating Your Fireplace
b) Clearances
c) Combustible Mantel Clearances
d) Framing & Finishing
e) Venting. See the "Venting Introduction" to
"Venting Arrangements" sections.
2. Assemble Standoffs. Refer to the "Unit Assembly
Prior to Installation" section. (NOTE: must be
done before installing unit into fireplace.)
3. Install flue. See the "Horizontal Installations" to
"Installation Procedures" sections.
4. Install 4 AA batteries into receiver battery box.
Connect receiver to wiring marked receiver,
this will enable operation of the appliance
manually when position in "ON" position.
Note:
The wire harness (marked receiver) is
located near the gas valve and will need to be
routed to the exterior of the fireplace from either
the left or right hand side of the appliance prior
finishing.
5. Supply 240 volt power to appliance. This
will be required to operate lights and highly
recommended to operate gas valve. AA Batteries
serve as back up only if 240 volt power is lost.
6. Make gas connections. Test the pilot. Must be as
per diagram. Refer to the "Gas Line Installation"
& "Pilot Adjustment" sections.
7. Install standard and optional features. Refer to
the following sections where applicable:
a. Safety Glass
b. Firebox (inner) glass
c. Log Set
d. Fireglass
e. Ceramic stones or other approved media
f. Painted or enamel (panels required)
g. Optional Framing Kit
h. HeatWave Kit
8. Plug 3 prong plug into the receptacle.
9. Final check.
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly and operation fully explained to customer.
This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label 28,500 Btu/h NG/
LP) after burning appliance for 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that causes
sooting or carboning that results in damage
is not the responsibility of the manufacturer.