30
|
City Series ACC40E
installation
1. Frame in the enclosure for the unit with framing material
Note: When constructing the framed opening ensure there is sufficient
access to install the gas lines,electrical. Also the wiring harness must
be wall mounted using the receptacle provided with the appliance. The
wiring harness will be located on the right hand side of the appliance if
facing the unit from the front. This must be done prior to any finishing.
2. For exterior walls, insulate the enclosure to the same degree as the
rest of the house, apply vapour barrier and plasterboard, as per local
installation codes. (Do not insulate the fireplace itself.)
WARNING:
Failure to insulate and add vapor barriers to the inside of
the exterior wall will result in operational and performance problems
including, but not limited to: excessive condensation on glass doors,
poor flame package, carbon, blue flames etc. These are not product
related issues.
3.
IMPORTANT:
The interior chase (back and sides) regardless
where appliance is placed within the home also requires the use of
plasterboard. All seams/joints MUST be sealed using plasterboard
tape and mud. As this appliance has been designed with all hot air
escaping through the enclosure using the ventilation grills, if hot air
is trapped as a result of the hot air escaping through joints or other
openings within the enclosure, this will change the clearances within
the enclosure causing the enclosure to over heat.
Note that in all applications while there is a zero clearance to com-
bustibles to the unit, all clearances to combustibles from the venting
inside the chase still applies. Please see venting clearances in the
specific product manual.
4. Combustible material (plasterboard, wood, wood panels, etc.) may
be brought up to this appliance (top,bottom and sides)
5. Ensure that the material being used does not encroach anywhere
in the area of the glass. This would cause dangerous operating
conditions.
6. This appliance comes with a 13mm lip at top, sides and bottom to hide
the ends of the drywall. The 13mm side and bottom, front and bottom
side lips supplied with the appliance can alternatively be removed and
replaced with J Style Trim or Metal Corner Bead purchased at your
local hardware store to cover cut/exposed edges of the combustible
facing material or any other finishing materials being used. Six (6)
screws secure the bottom front lip. Two (2) secure the bottom side
lips and 2 secure the side if deciding to remove these. These will be
hidden so the outer panels (if installed) will need to be removed to
access the screws. See outer panel removal in this manual.
7. This appliance can also be recessed (using combustible materials)
with a hearth in front of the appliance. This can also extend to the top.
8. The wall behind the unit must be closed off.
Framing and Finishing Inset Installations
**Combustible material may extend a minimum of 13mm and to a
maximum of 130mm from the Front top. See mantle clearance chart
for details. The base and side (with smaller glass) have no limit when
it comes to how far the combustible material may extend out from the
appliance. Ensure that no material encroaches anywhere in the area
of the glass as these are defined by the finishing lip above, below and
to the sides of this appliance.
Note: an offset screwdriver is provided with the appliance for ease of removal/
installation.
Finishing lip
Содержание ACC40E City Series
Страница 79: ...City Series ACC40E 79 notes ...
Страница 85: ...City Series ACC40E 85 notes ...
Страница 86: ...86 City Series ACC40E ...