66
|
City Series ACC40E
maintenance
919-743
11.25.16
CC40RE/CC40LE OUTER PANELS
Outer side panel install
Outer base panel install
Note: Install inner safety glass prior to installation of outer panels-see
instructions in manual
1. Attach Regency logo to the right hand side of outer front panel. The
magnets will be positioned under the outer front base panel to secure
the logo. The logo should be about 76 mm from the right hand corner
of the outer base. Install outer front and side base panel.
2. Install side panels - the side panels are secured in place by existing
magnets in the unit.
3. Install outer safety glass.
4. Reverse steps to remove panels.
Location of
Regency Logo
2