![Regency Fireplace Products 686-927 Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/regency-fireplace-products/686-927/686-927_owners-and-installation-manual_1433845028.webp)
28
|
City Series CB60EPV
installer's information
Locating Your Gas Fireplace -
Bay Install
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat, solid,
continuous surface For example a wood, metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3. The CB60EPV Direct Vent Gas Fireplace can
be installed framed out into the room as in D
and E. See Diagram 1.
4. For bedroom installations, check with local
codes before installation. This appliance is
offered with a remote control.
5. The CB60EPV Direct Vent Gas Fireplace is
approved for alcove installations, see "Clear-
ances" section for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note:
For vent terminations refer to "Exterior
Vent Termination Locations" section.
E
Diagram 1
D) 3 sided-CB60EPV (corner install)
E) 3 sided-CB60EPV
Locating Your Gas Fireplace -
Corner Install
1. When selecting a location for your fireplace,
ensure that the clearances are met.
2. The appliance must be installed on a flat, solid,
continuous surface For example a wood, metal
or concrete floor or in a raised (on the wall) ap-
plication. The appliance must be installed on
a metal or wood panel extending the full width
and depth of the appliance.
3. The CB60EPV Corner Conversion Gas Fire-
place can be installed in a recessed position
or framed out into the room as in A and B. See
Diagram 1.
A
B
Diagram 1
A) Corner Left
B) Corner Right
4. For bedroom installations, check with local
codes before installation. This appliance is
offered with a remote control.
5. The CB60EPV Corner Conversion Gas Fire-
place is approved for alcove installations, see
"Clearances" section for details.
6. We recommend that you plan your installa-
tion on paper using exact measurements for
clearances and floor protection before actually
installing this appliance. Have an authorized
inspector, dealer, or installer review your plans
before installation.
Note:
For vent terminations refer to "Exterior
Vent Termination Locations" section.