City Series CB60EPV
|
21
owner's information
Levers to lower firebox glass
tooltip
6. Support the glass with one hand and open the 9 lower clamps.
5. Pull the 3 lower glass gasket pads forward to release the glass.
7. Locate the 2 levers below the glass and turn them both 90° in a clockwise
direction to lower the firebox glass panel.
8. Carefully lean glass forward onto support.
Glass panel--leaning on support
Lower clamps (x9) in open position
Push down on levers to lower glass panel
Gasket pad
NOTE:
The firebox glass may remain propped on the glass supports to clean
the interior surface. Use care when cleaning -- do not apply excessive force
or pressure.
9.
To remove the firebox glass panel from the unit:
tilt the glass forward
gently onto the glass supports, grip both suction clamps and lift the glass
up and out of the unit.
10. To install glass--reverse steps.
IMPORTANT:
Remove glass panel completely when installing or removing
panels, logs, media, etc. to avoid causing any damage to the glass.