City Series CB60EPV
|
37
installation
Framing Dimensions Corner Kit - Corner Install (Left Corner)
NOTE:
Framing may be constructed of combustible material and does not require steel studs.
Note: A combined minimum of
180 square inches of open area
is required for the convection air
outlet to cool the enclosure. En-
sure clearances for Convection Air
Outlets are met.
See clearances CB60EPV in this
manual as there are different meth-
ods as to how this can be achieved.
NOTE: Unit cannot be load-bearing. All finishing materials must be supported by the framing.
Note: This appliance must be in-
stalled on a level and solid surface
such as a plywood floor which must
be the full width and depth of the
appliance.
Framing
Dimensions
Description
Corner Kit
A
Framing Height
44-3/4” (1137mm)
B*
Framing Width
71-1/4" (1810mm)
C*
Framing Depth
20-5/16" (516mm)
D
Unit Base to Top Enclosure (Min.)
81-1/4"(2038mm)
G
Vent Centerline Height
58-3/16" (1478mm)
Max 2 x 6
Max 2 x 6
*
*
Note: Unit must be installed onto a solid back wall
- do not install directly onto studs.
*Note:
The framing width (B) and framing depth (C)
does not take into account drywall/wood or simi-
lar materials against the back wall. The framing
width/depth will need to change based on the
thickness of the material
Example B : 71 1/4" framing width + 1/2" drywall
= 71 3/4".
Example C : 20-5/16" framing depth + 1/2" drywall
= 20 13/16".