16
MO 3, MO 3.3, MO 3.4, MO 3.5
..................................................................................................................................... current 4 up to 20 mA
Power outputs:
.................................................................................................................. 2x relay 5A/250V AC
Digital outputs:
.............4x LED (supply, error, adjustment, "opening", "closing" - with two-colour LED)
Error status:
....................................................................................................... control switch 24 V, 2W - POR
Reaction at error situation:
transmitter error - error message LED
Control signal missing:
...................................................................................................... error message LED
SYS mode:
........................................................................................................................... error message LED
Adjusters:
.................................................................................................................. communication connector
................................................................................................................. 2x calibrating and adjusting button
2.2.1 Mechanical connection
•
By flange F10, F14 resp. F16 (ISO 5210, DIN 3338)
•
By flange
φ
220 resp.
φ
135 (GOST R 55510)
Main and connecting dimensions are presented in
dimensional drawings
.
2.2.2 Electric connection
a) Electric actuator
to terminal box type (X)
):
- max. 32 terminal connectors , crosscut of connecting wire max. 2,5 mm
2
for
version without contactors, resp. max. 24 terminal connectors, crosscut of connecting wire max. 2,5 mm
2
and
max. 6 terminal , crosscut of connecting wire max. 1,5 mm
2
for version with contactor
- 2 cable bushings from control box – M25x1,5 cable diameter 12,5 to 19 mm
to connector (XC):
- (max. 32 poles - the crosscut of connecting wire 0, 5 mm
2
):
- 2x cable bushings-M20x1,5 and M25x1,5 cable diameter from 8 -14,5 mm and 12,5 - 19 mm
b) 3~ electric-motor
in a terminal board make:
.................................................. through bushing M25 to the motor terminal board
in connector make:
............ to common connector
(XC)
•
with protection terminal:
external and internal, mutually connected and marked with protection earthling mark.
Electric connection:
according to wiring diagrams.
Содержание MO 3
Страница 35: ...MO 3 MO 3 3 MO 3 4 MO 3 5 33 7 Enclosures 7 1 Wiring diagrams Wiring diagrams MO...
Страница 36: ...34 MO 3 MO 3 3 MO 3 4 MO 3 5...
Страница 37: ...MO 3 MO 3 3 MO 3 4 MO 3 5 35 Wiring diagrams MO with controller...
Страница 41: ...MO 3 MO 3 3 MO 3 4 MO 3 5 39 4 x tooth F10 shape D F10 shape C DIN 3338 F10 shape E ISO 5210...
Страница 42: ...40 MO 3 MO 3 3 MO 3 4 MO 3 5 Mechanic connections for EA MO 3...
Страница 43: ...MO 3 MO 3 3 MO 3 4 MO 3 5 41...
Страница 45: ...MO 3 MO 3 3 MO 3 4 MO 3 5 43 Dimension drawings for EA MO 3 5...
Страница 46: ...44 MO 3 MO 3 3 MO 3 4 MO 3 5 Dimension drawings for EA MO 3 4...
Страница 47: ...MO 3 MO 3 3 MO 3 4 MO 3 5 45 Dimension drawings for EA MO 3 3...
Страница 50: ...48 MO 3 MO 3 3 MO 3 4 MO 3 5 Mechanic connections for EA MO 3 4 with connect adapter...
Страница 51: ...MO 3 MO 3 3 MO 3 4 MO 3 5 49...
Страница 53: ...MO 3 MO 3 3 MO 3 4 MO 3 5 51 Mechanic connections for EA MO 3 5 with connect adapter F14 shape A ISO 5210...