21
As foreseen by the correct muting sequence, occupation and subsequent
freeing of sensor 3 determines the end of the muting cycle. Each time
sensor 3 is involved other than in the way envisaged, fail muting status is
generated. For this reason:
F
muting sensor 3 cannot be used in bi-directional systems in
muting sensor 3 cannot be used in bi-directional systems in
which the pallet enters and leaves the danger area through a
which the pallet enters and leaves the danger area through a
single controlled access (fig. 12).
single controlled access (fig. 12).
Figure 12
Entry/exit type bi-directional system: sensor 3 cannot be used.
To avoid interference between the light barrier and the muting sensors,
the light barrier must be assembled so that the synchronism beam is on
the part opposite the muting beams.
In ARGOLUX AS safety barriers, the synchronism beam is generated by the
ASR receiver and is the first beam starting from the output connector part:
F
assemble the light barrier so that the output connectors are
assemble the light barrier so that the output connectors are
on the part opposite the muting sensors (fig. 13).
on the part opposite the muting sensors (fig. 13).
Figure 13
Assemble the barrier with the connectors to the top.