INSTALLATION
The AU S3M2 control unit used with the ARGOLUX AS series safety
barriers is a type 2 electro-sensitive protection system.
As envisaged by the prEN 50100 standard project, in a type 2 safety
device, faults or malfunctions must be detected during the test phase.
Before installing the ARGOLUX AS series safety system, make sure that:
F
the danger level of the machine is such as to permit use of
the danger level of the machine is such as to permit use of
type 2 electro-sensitive safety devices.
type 2 electro-sensitive safety devices.
In a type 2 safety device, the test is mandatory, i.e. the relays are
energized only after the test command has been sent and only if the test is
passed.
Before installing the ARGOLUX AS series safety system, make sure that:
F
the machine or the processing cycle are compatible with
the machine or the processing cycle are compatible with
functioning of a type 2 safety device.
functioning of a type 2 safety device.
The work cycle or the start of the dangerous movement must begin only
using the control device. In particular:
F
the safety system must be used only as stopping device and
the safety system must be used only as stopping device and
not as machine control device.
not as machine control device.