15
TECHNICAL DATA
Power supply
Vdc
24
±
20%
Power consumption
W
8
Output relays (*)
2 N.O. contacts 2A 125Vac
1N.C. contact 2A 125Vac
Self-test output
1 N.O. contact 0,5A 25Vac - 60Vdc
contact open in case of unusual operation
Muting sensors
DARK ON
Relay output 1 N.O. contact or PNP static output
Muting sensors
output feature
100mA 24Vdc
Muting signaling
device
24Vdc
0,5
÷
5W
Response time (**)
ms
≤
15
Minimum duration of the
test command
ms
10
Reset time from start of the test
ms
150
Muting signals
response time
ms
300
Electrical connections (***)
Terminal blocks
Cable lenght (****)
m
100 max
Working temperature
°C
0
÷
55
Sealing (housing)
IP 40
Sealing (terminal blocks)
IP 2X
Mechanical mounting
Quick mounting on rail according
to EN 50022-35
Dimensions
mm
152 x 73 x 118
Weight
g
800
ORDERING CODE
1201707
(*)
Refer to "Load features" in the Electrical connections chapter (page 21).
(**)
Output circuit de-energization delay in case of field interrupted.
(***)
Use isolated lugs.
(****) We reccomend shielded cable where the level of electrical disturbances is higher than the
specified IEC 801/4 level IV.