19
•
the area delimited by the points of interception and freeing of the
beams of sensors 1 and 2 by the pallet must be as small as possible
(or be suitably protected) so as to avoid accidental passing through
the light barrier with muting activated (fig. 9).
Figure 9
Keep the dimensions of the muting activation and de-activation areas as small as possible.
If sensor 3 is to be used, particular attention must be paid when
positioning this.
F
When it is freed, sensor 3 causes ending of the muting cycle
When it is freed, sensor 3 causes ending of the muting cycle
and the possibility of starting a new muting cycle.
and the possibility of starting a new muting cycle.
F
Sensor 3 must be freed when the light barrier and muting
Sensor 3 must be freed when the light barrier and muting
sensors 1 and 2 have been freed by the pallet.
sensors 1 and 2 have been freed by the pallet.
Usually, the sensor is positioned so that the beam is crosswise to the
direction of feed of the pallet. The beam may be parallel to the ground or
slightly sloping so as to extend the sensing range (fig. 10).
Figure 10
Pallet that advances in a frontwise direction towards sensor 3.