The test control must be located outside the danger area and in such a
way as to assure unobstructed visibility of the operating area.
Before installing the ARGOLUX AS series safety system, also check that:
•
The machine can be controlled electrically.
•
It is possible to interrupt any dangerous action of the machine
promptly. In particular, the stopping time of the machine must be
known, measuring this where necessary.
Also:
•
Site the AU S3M2 control unit in an environment with at least IP54
protection rating.
•
Check that the temperature where the system is installed is compatible
with the temperature parameters indicated in the technical data.
•
For applications in the food and beverage industry consult the factory
to check the compliance with the materials and chemical agents
involved.
If necessary, in the case of technical safety questions, consult the safety
authorities of your country or the competent industry association.
POSITIONING
POSITIONING
Safety distance.
Safety distance.
The light barrier must be positioned at a distance that is greater than or
equal to the minimum safety distance S so that hazardous points can be
reached only after stopping the dangerous action of the machine (fig. 8).
Figure 8
Comply with the minimum safety distance.