• Function #3, green LED flashes 3x short: Low-voltage for LiPo rechargeable batteries
For NiCD/NiMH rechargeable batteries the low-voltage protection must be switched off (factory setting).
If LiPo rechargeable batteries are used, then you must ensure that the low-voltage protection is activated
(e.g. 3.0 V per cell).
If the low-voltage protection is activated, the drive control unit measures the rechargeable battery voltage immediately
after it is switched on. At a voltage lower than 9V, the unit assumes a 2-cell LiPo rechargeable battery is in place, at
voltages between 9.0 and 12 V it assumes a 3-cell LiPo rechargeable battery is in place.
If the rechargeable battery voltage is lower than the set value (e.g. 3.0 V per cell, power cut-out at 6.0 V when 2-cell
LiPo rechargeable battery is used), the motor is shut off in order to protect the battery.
• Function #4, green LED flashes 4x short: Start mode when driving off
Depending on this setting, the take-off/start speed is more or less powerful. Note that the two settings "fast" and
"very fast" require a correspondingly powerful rechargeable battery which is capable of providing the appropriate
current during take off.
• Function #5, green LED flashes 1x long: Maximum braking strength
The drive control unit allows proportional braking strength depending on the setting of the transmitter lever. The
maximum braking power at full lever extension can be adjusted to 25%, 50%, 75% and 100% (factory setting).
A high setting (e.g. 100%) decreases braking distance but has a negative effect on the lifetime of the cogs.
• Function #6: green LED flashes 1x long 1x short: Max. reverse speed
The maximum speed for reversing can be programmed with this function. Settable values are 25%, 50% (factory
setting) 75% und 100%. To allow the model to be easily steered when reversing, the factory setting is "50%".
Please note that the drive function (see "Function #1") must be programmed correspondingly ("forward/brake/reverse"),
otherwise the reverse setting is pointless.
• Function #7: green LED flashes 1x long, 2x short: Minimum braking strength
This is where you can set the braking strength, when the braking process begins (depending on the setting of the
transmitter lever).
The presetting (factory) is the same braking strength as the handbrake function ( see "Function#2"), but values of
20% and 40% can also be programmed.