Drop Counter (Packets)
: Number of ARQ timeouts.
Air Counter (Bytes)
: Total number of bytes transmitted over the wireless interface.
Air Counter (Packets)
: Total number of packets transmitted over the wireless interface.
Tx Throughput (Mbps)
: Current transmitted throughput.
Rx
Statistics for the receiver section of the air interface.
Air Counter (Bytes)
: Total number of bytes received.
Air Counter (Packets)
: Total number of packets received.
Air CRC Counter (Packets)
: Total number of packets received with CRC errors.
Rx Throughput (Mbps)
: Current received throughput.
Tx Power Control
Use these settings to manually adjust the output characteristics of the RDL-2000.
Note: These manual settings override automatic system adjustments for modulation
settings and may result in over-the-air errors. Changes are not saved permanently and
the saved configuration is restored on the next system reboot.
Tx Power (tx pwr table)
: Use this control to manually adjust the Tx power setting. Changes
made using these controls are sent to the RDL-2000 by clicking the
Submit
button.
RF Attenuator (0-31)
: Use this setting to attenuate the signal. Changes made using the
up/down controls are sent immediately to the RDL-2000. Values entered in this field are sent
to the RDL-2000 by clicking the
Submit
button.
Tx Power Reg (0x00-0xff)
: Changes made using the up/down controls are sent
immediately to the RDL-2000.
Get Config
: Click this button to load the saved Tx power settings from the RDL-2000.
Submit
: Click this button to send the
RF Attenuator
and
Tx Power Reg
settings to the
RDL-2000. Changes made in this screen are not saved in the RDL-2000.
Utility Variables
These settings are for factory test only.
Reset Logger
This control is for factory test only.