Packet received at subscriber Ethernet interface: 

Each packet with this VID (

Connection

 VLAN ID field) has the matching VLAN tag 

(outermost only) removed and is forwarded over the wireless interface to the sector 
controller.  

Packet received at subscriber wireless interface (from sector controller): 

A VLAN tag is added (outermost) and set to the VID (

Connection

 VLAN ID field) for 

this 

Connection

. The packet is forwarded to the subscriber Ethernet port.  

Pass-through

: Select pass-through to create a 

Connection

 to process all untagged 

packets and packets where the outermost VLAN ID tag does not match the VID 
(

Connection

 VLAN ID field) for with this 

Connection

. Only one pass-through 

Connection

 

can be defined for each subscriber. If a pass-through 

Group

 is not configured, all 

untagged packets received at the subscriber Ethernet ingress port are discarded.

 

Packet received at subscriber Ethernet interface: 

The packet is forwarded unmodified over the wireless to the sector controller. 

Packet received at subscriber wireless interface (from sector controller): 

The packet is forwarded unmodified to the subscriber Ethernet port.  

Connection VLAN ID

: Enter the VLAN ID tag associated with this 

Connection

 definition. 

This field is used only when 'Tagged' is selected in the 

Connection

 Tagging Mode field.  

Default priority

: Enter the default 802.1p priority setting. 

The  default  priority  setting  is  used  only  when  the 

Connection

  Tagging  is  set  to  'pass-

through'  mode  and  the  associated 

Group

  Tagging  Mode  is  set  to  'Tagged'.  The 

Connection

 Default Priority value is used when adding the 802.1Q tag (

Group

 VLAN ID) to 

the packet being forwarded. 

Parent  Link  ID

:  Enter  the 

Link

 

ID

  for  this 

Connection

.  This  is  the  unique  identification 

value created automatically when the subscriber 

Link

 was added. See 

Links

 

List

 below. 

Links

 

List

: Click this text (right side of screen) to display a list of existing 

Link IDs

Parent Group ID

: Enter the 

Group

 

ID

 for this 

Connection

. This is the unique identification 

value created automatically when the subscriber 

Link

 was added. See 

Groups

 

List

 below. 

Groups

 

List

: Click this text (right side of screen) to display a list of existing 

Group IDs

Wireless Traffic Parameters 

The sector controller allocates bandwidth for all subscribers using the Weighted Round 
Robin  algorithm  with  the  combined  total  of  all  QoS  levels  acting  as  weights.  The 
aggregate QoS settings affect packet delay and jitter values for the entire sector.  

It is 

strongly

 recommended to calculate 

DL QoS

 and 

UL QoS

 levels using the Redline AN-

80i  PMP  Configuration  Tool  --  the  QoS  levels  for  each 

Connection

  can  be  read  directly 

from  the 

QoS

  column  in  the 

Connection  ID  Configuration

  section.  To  manually  determine 

these  settings,  identify  the  maximum  UL  and  DL  burst  rate for  the  associated 

Link

  and 

calculate the highest available level using the formula: 

Burst Rate - 1

DL QoS Level

: Enter the QoS level for downlink unicast traffic for this connection.  

UL QoS Level

: Enter the QoS level for uplink unicast traffic for this connection. 

Содержание AN80IE

Страница 1: ...70 00072 01 07 Proprietary Redline Communications 2010 Page 1 of 106 Sept 18 2008 AN 80i System PTP PMP User Manual ...

Страница 2: ...com Sales Inquiries North American nainfo redlinecommunications com Toll free sales 1 866 633 6669 International intlinfo redlinecommunications com Support www redlinecommunications com support support_portal html Document Control 70 00072 01 06 AN 80i_User_Manual 20080918c doc Disclaimer The statements configurations technical data and recommendations in this document are believed to be accurate ...

Страница 3: ... Brackets 15 2 4 Grounding Connection 15 2 5 Indoor Power Block PoE Power Adapter 16 2 5 1 AC Power Adapter 16 2 5 2 DC Power Adapter 16 2 6 Antenna Alignment 17 2 6 1 Web Page Alignment 17 2 6 2 Audible Alignment 17 3 Web Interface PTP 18 3 1 System Login 18 3 2 System Menu 19 3 3 System Information 20 3 3 1 General Information 20 Dashboard 20 3 3 2 General Information 23 General 23 Ethernet 24 W...

Страница 4: ...s Traffic Parameters 56 4 5 Browse Screens 57 4 5 1 Links Screen 57 4 5 2 Groups Screen 58 4 5 3 Connections Screen 59 4 6 Statistics Screens 60 4 6 1 Link Statistics 60 4 6 2 Group Statistics 61 4 6 3 Connection Statistics 62 4 6 4 System Status PMP Wireless Statistics 63 4 7 Quick Configuration Guide 63 4 7 1 Configure Pass Through Operation 64 Step 1 Create New Link for Each Subscriber 64 Step ...

Страница 5: ... 4 1 PTP Status Codes 88 6 4 2 PMP Status Codes 89 7 Appendices 90 7 1 AN 80i Technical Specifications 90 7 2 AN 80i PoE Power Adapter Specifications 92 7 3 Antenna Mounting Bracket Matrix 92 7 4 Legacy Products Not Available to Order 93 7 5 ETSI Certified Antennas 94 7 5 1 3 3 3 8 GHz Radio ETSI Certified Antennas 94 7 5 2 5 8 GHz Radio ETSI Certified Antennas 94 7 5 3 5 4 GHz Radio ETSI Certifie...

Страница 6: ... 13 Web Default System Users 40 Table 14 Web Performing a Spectrum Sweep 47 Table 15 PMP Basic Pass Through Group Settings 50 Table 16 PMP Packet Classification 50 Table 17 PMP Maximum Achievable UBR 52 Table 18 PMP Basic Pass Through Group Configuration Settings 65 Table 19 CLI Command Summary 66 Table 20 CLI Root Mode Commands 67 Table 21 CLI chgver 67 Table 22 CLI clear 68 Table 23 CLI del 68 T...

Страница 7: ...SI Certified Antennas 5 8 GHz Operation 94 Table 55 Spec ETSI Certified Antennas 5 4 GHz Operation 95 Table 56 Spec ETSI Certified Antennas 5 15 5 35 GHz Operation 95 Table 57 Spec FCC IC Certified Antennas 5 8 GHz PTP Operation 96 Table 58 Spec FCC IC Certified Antennas 5 8 GHz PMP Operation 96 Table 59 Spec FCC IC Certified Antennas 5 4 GHz Operation 97 Table 60 Spec FCC IC Antennas 5 25 5 35 GH...

Страница 8: ...load Software Screen 42 Figure 17 Web SNMP Configuration Screen 43 Figure 18 Web SNMP Community Configuration Screen 44 Figure 19 Web SNMP Trap Configuration Screen 45 Figure 20 Web Spectrum Sweep Screen 46 Figure 21 Web Spectrum Sweep Results 47 Figure 22 PMP Main Menu 48 Figure 23 PMP Basic Pass through Group Configuration 49 Figure 24 PMP VLAN Tagged Traffic Example 49 Figure 25 PMP Wireless Se...

Страница 9: ...t be contracted to a professional installer 2 Read this user manual and follow all operating and safety instructions 3 Keep all product information for future reference 4 The power requirements are indicated on the product marking label Do not exceed the described limits 5 Use only a damp cloth for cleaning Do not use liquid or aerosol cleaners Disconnect the power before cleaning 6 Disconnect pow...

Страница 10: ...sional installer who must follow local and national codes for electrical grounding and safety Failure to meet safety requirements and or use of non standard practices and procedures could result in personal injury and damage to equipment A direct lightning strike may cause serious damage even if these guidelines are followed All outdoor wireless equipment is susceptible to lightning damage from a ...

Страница 11: ...etween the antenna of this device and persons during device operation Table 1 FCC IC RF Recommended Safe Separation Distances Frequency GHz Mode Separation Distance 3 650 3 700 PTP PMP 130 cm 52 in or more 3 3 3 8 PTP PMP 130 cm 52 in or more 4 9 5 3 PTP PMP 255 cm 101 in or more 5 4 PTP PMP 40 cm 16 in or more 5 8 PMP 20 cm 8 in or more PTP 310 cm 122 in or more To ensure compliance operation at ...

Страница 12: ...nges or modifications not expressly approved by Redline Communications could void the user s authority to operate the equipment 5 Do not operate an AN 80i outdoor transceiver until you have confirmed the FCC specific options key is loaded and active operating range restricted to 3650 3700 MHz When the FCC specific options key is installed the operator is not able to set an RF frequency that exceed...

Страница 13: ...ons un fil de télécommunication ayant un calibre minimum de 26 AWG doit être utilisé 5 Reminder to all the BWA system installers Attention to Section 820 40 of the NEC which provides guidelines for proper grounding and in particular specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as is practical 6 AN 80i must be instal...

Страница 14: ...ing a time division duplexing TDD RF transceiver to transmit and receive on the same RF channel The main AN 80i features include advanced technologies to address inter cell interference enhanced security features through a proprietary over the air encryption scheme and Automatic Transmitter Power Control ATPC to automatically achieve and maintain optimum performance The AN 80i outdoor unit is hous...

Страница 15: ...ives DC power and exchanges data with the indoor network through the Ethernet port The AN 80i Ethernet port connects to the PoE Adapter using a weatherproof Cat 5e Ethernet cable The Ethernet port is a female RJ 45 connector 2 2 RF Port The RF port is used to send and receive RF signal to from the antenna A short coaxial cable is provided to connect the transceiver to an external antenna The RF po...

Страница 16: ...r adapter provides power and connection to a local Ethernet network 2 5 1 AC Power Adapter The AC power adapter input is auto sensing 110 220 240 VAC 50 60 Hz Figure 3 Intro Indoor Power over Ethernet PoE Module AC Model 2 5 2 DC Power Adapter The DC power adapter input is auto sensing 18 60 VDC Figure 4 Intro Indoor Power over Ethernet PoE Module DC Model ...

Страница 17: ...t SINADR ratio The web page alignment tool provides continuous updates 1 second intervals of the measured RSSI received signal strength indication and SINADR Signal to noise and distortion ratio This web page can be accessed from a laptop computer and most web enabled handheld devices Use the following URL to access the AN 80i alignment web page http AN 80i IP Address usr aa html For example http ...

Страница 18: ... 3 1 System Login On the PC open a browser Internet Explorer 6 or higher recommended For new systems enter the default IP address 192 168 25 2 The following dialog should be displayed Figure 5 Web Login Screen Login to the AN 80i using your user name and password See Table 13 Web Default System Users on page 40 for the factory default usernames and passwords If the IP address username and or passw...

Страница 19: ... login the General Information screen is displayed On the left is a menu of all available screens Point and click on the blue text of the menu to display that screen Figure 6 Web System Menu The administrator admin has unrestricted access to all screens All other users have viewing access only See 3 7 Users Management on page 39 for details ...

Страница 20: ...reen Displays time obtained from user s Web browser Wireless Link LED The Wireless Link LED lights solid green when the wireless link is established If the LED is off it may indicate one of the problems listed in the following table Table 2 Wireless Link LED Diagnostics Symptom Possible Problem Solution No wireless link Link name does not match A PTP wireless link can be established only between p...

Страница 21: ...mptom Possible Problem Solution No Ethernet Link Poor cable connection to Ethernet equipment Carefully check all cable connections Wrong type of cable to Ethernet equipment If the Ethernet is connected to a router a straight through cable is required If the Ethernet is connected to a switch a crossover cable is required System processor malfunction Apply short reset or long reset The connected Eth...

Страница 22: ... typical to have intermittent packet collisions If the LED is blinking it may indicate one of the problems listed in the following table Table 7 Ethernet Link Collision LED Diagnostics Symptom Possible Problem Solution Link Collision FD LED blinks Collisions are normal for half duplex links It is strongly recommended to manually configure all devices to matching speed and duplex settings If manual...

Страница 23: ...the AN 80i System Mode The system designated as PTP Master establishes and manages the bi directional data link with a remote end AN 80i Only one system in a wireless link must be set for PTP Master mode PTP Master AN 80i begins transmitting automatically sends poll messages to locate the remote AN 80i Slave and negotiates operating settings for the link PTP Slave AN 80i waits passively monitoring...

Страница 24: ...N 80i chassis IP Address User assigned IP address of this AN 80i IP Subnet Mask User assigned IP subnet mask Default Gateway Address User assigned IP address of the default router or gateway Wireless RF Link Established Status of the wireless link Yes RF link successfully established with remote end AN 80i No RF link not established with remote end AN 80i Uncoded Burst Rate The current uncoded bur...

Страница 25: ...end AN 80i No RF link has not been established with the remote end AN 80i Uncoded Burst Rate The negotiated uncoded burst rate UBR for the link System Mode The PTP Master establishes and manages the wireless link with the remote end AN 80i Each wireless link must have only one PTP Master PTP Master An 80i transmits automatically sending poll messages to the remote AN 80i and negotiating the UBR mo...

Страница 26: ...Packets Discarded Total valid Ethernet frames received on the Ethernet port that are discarded due to lack of buffer space Tx Packets Number of packets transmitted on the Ethernet port including Ethernet frames and error correction bytes Wireless Statistics Link ID A unique Link ID value is generated automatically when a new link is added Received Signal Strength Min Minimum measured RSSI value Re...

Страница 27: ...Configuration Load OK 1002 System Configuration Save OK 1003 EEPROM Directory Load OK 1004 EEPROM Directory Save OK 1005 User Configuration Load OK 1006 User Configuration Save OK 1007 Network Configuration Load OK 1008 Network Configuration Save OK 1009 Network Configuration OK 1010 Version Ctrl Data Load OK 1011 Version Ctrl Data Save OK 1012 System Description Load OK 1013 System Description Sa...

Страница 28: ...ned OK 1044 ID tables not changed OK 1045 ID modified OK 1046 RF frequency validation OK 2001 System Configuration Load Error 2002 System Configuration Save Error 2003 EEPROM Directory Load Error 2004 EEPROM Directory Save Error 2005 User Configuration Load Error 2006 User Configuration Save Error 2007 Network Configuration Load Error 2008 Network Configuration Save Error 2009 Network Configuratio...

Страница 29: ...Save Error 2034 HTTP User Mgm Invalid password 2035 HTTP User Mgm Invalid User 2036 HTTP User Mgm Chg User Attributes Error 2037 SNMP Configuration Load Error 2038 SNMP Configuration Save Error 2039 Invalid Options Key 2039 SNTP Time received Error 2040 MAC Initialization Error 2041 MAC Busy 2042 ID database corrupted 2043 Invalid ID 2044 Max ID number reached 2045 Int Procs programming Error 2046...

Страница 30: ...e name may be up to thirty 30 alpha numeric characters including a z A Z 0 9 dash and underscore _ System Details Enter additional descriptive details about this AN 80i The name may be up to thirty 30 alpha numeric characters including a z A Z 0 9 dash and underscore _ System Location Enter additional descriptive details about this AN 80i The name may be up to thirty 30 alpha numeric characters in...

Страница 31: ... enter the network address of the SNTP server in the SNTP Server IP Address field SNTP Server IP Address Enter the network address of the SNTP server Valid only when the SNTP Enable field is checked Polling Interval Enter the SNTP polling interval hours Time Zone GMT Enter the hours offset from GMT for this time zone Valid only when the SNTP Enable field is checked Syslog Enable Check this box to ...

Страница 32: ...ter and PTP Slave can be managed through the local Ethernet port using untagged traffic Over the air management is possible only after creating a pass through group and pass through connections for each PTP Slave When Mgmt Tag Enable is enabled this PTP Master or PTP Slave can be managed only using VLAN traffic tagged with the value specified in the Mgmt VID field Over the air management is possib...

Страница 33: ...es on page 99 for available channels Use the Autoscan feature to enable use of multiple channels When the Auto Scan field is not checked the PTP Slave will only register with a PTP Master operating at the frequency specified in the RF Freq MHz field Important To minimize interference the channel frequencies for AN 80i links operating in close proximity should be separated by a minimum of the chann...

Страница 34: ...range settings and add these to the Local Frequency Range list if valid To save changes to non volatile memory return to the Configuration Screen and click the Save button at the bottom of the screen Delete Frequency Range Index Select the index value for the scan interval delete from the Local Ranges table Delete Click the Delete button to permanently remove the selected scan interval Local Frequ...

Страница 35: ...Local Frequency Ranges are ignored The Remote Frequency Ranges remain in effect until the PTP Slave is rebooted Tx Power dBm Enter the transmit power level dBm This setting is for the transceiver output only The actual EIRP depends on the gain of the connected antenna Refer to the following tables to determine the maximum transmit power level available at each modulation setting When ATPC is enabl...

Страница 36: ... suspended until the thirty minute time interval expires for at least one channel Important Where DFS is required by regional regulations this feature is permanently enabled at the factory and can not be disabled by the installer or end user Antenna Gain Enter the gain dBm for the system antenna It is important that the Antenna Gain setting matches the actual antenna gain If the antenna gain is se...

Страница 37: ... following loss of connectivity on the wireless interface Following this interval the Ethernet port will be automatically re enabled to allow management of the AN 80i Important When Ethernet Follows Wireless Timeout is enabled external switches routers monitoring the Ethernet port must be programmed to not switch automatically when the Ethernet port function is restored the wireless interface may ...

Страница 38: ...se interval and reject reflections of the transmitted signal This setting is valid only when the Link Length Mode is set to Manual Link Length Measurements Unit Select the units for the Link Length field Mile Link length distance is displayed in miles Km Link length distance is displayed in kilometers Antenna Alignment Buzzer Enable Check this box to enable the antenna alignment audible tone gener...

Страница 39: ...ons associated with each group Important There must always be at least one administrator account active on the AN 80i You can not manage the AN 80i if all accounts are user Figure 14 Web System Password Screen Change User Settings Use this dialog to change the settings for an existing user User name Select an existing user to be modified Group Select the group to be associated with this username N...

Страница 40: ...Information X X View general system identification and configuration settings System Status X X View system information Ethernet statistics and wireless statistics System Log X X View the system status messages recorded by the AN 80i Configure System X View and adjust configuration system IP address management and wireless settings Upload Software X Upload a new software binary file Users Manageme...

Страница 41: ...ions Key field selects the preferred key If valid the selected key will be activated immediately when the Activate button is clicked This selection is not affected by switching software versions If the selected key expires temp or the mode is changed PTP PMP the AN 80i will switch to the standby key if valid Important If the active options key is a temporary key always enter and activate a purchas...

Страница 42: ...ps A TFTP FTP server is used to upload the new software image file from your computer to the AN 80i TFTP FTP server software must be installed and running on the computer you are using to upload the new software file In addition the AN 80i software binary file must be located in the default upload directory for the TFTP FTP server 1 Enter the IP Address of the computer running the TFTP FTP server ...

Страница 43: ...or delete community settings Figure 17 Web SNMP Configuration Screen SNMP Community Management Community Name Displays the SNMP community name for each entry maximum of eight entries Access Displays the access permissions for each SNMP community None Deny read and write permission for this community Read Grant read access permission only for this community Deny write permission Write Grant write a...

Страница 44: ...he settings Figure 18 Web SNMP Community Configuration Screen Index Display the unique reference number for this entry Community Name Enter or modify the SNMP community name for this entry Access Rights Select the access permissions for this entry None Deny read and write permission for this entry Read Grant read access permission only for this entry Deny write permission Write Grant write access ...

Страница 45: ...n Index Display the table position number for this entry Position 0 is the first entry IP Address Enter the IP address IPv4 associated with this SNMP alarm Port Enter the destination port address associated with this SNMP alarm Community Name Enter the SNMP community name for this entry Change Trap Click the Change Trap button to copy these settings to the community settings table This action does...

Страница 46: ...tification Codes on page 99 Step MHz Enter the frequency step MHz to use when scanning from the lowest to the highest frequency The step selection must be a multiple of 2 5 MHz i e 2 5 5 etc No of acquisitions Enter the number of times the frequency will be sampled at each step The recommended range is 10 to 100 samples When a potentially clear channel is identified reduce the frequency range and ...

Страница 47: ... Setting Description System Mode PTP Slave PMP Subscriber No action required Remote end will remain passive during sweep System Mode PTP Master PMP Sector Controller Use Web CLI to disable radio on remote end Use test function to save and remote end will restore radio operation automatically after 5 minutes Figure 21 Web Spectrum Sweep Results ...

Страница 48: ...are provides the following main features IEEE 802 1Q standard compliance VLAN Groups span subscribers Multiple VLAN Connections per subscriber Multiple TLS transport based on VLAN ID classification QoS provisioning with individual CIR setting per connection VLAN trunking with tag insert delete re map VLAN tagged management traffic 4 2 PMP Menu The following menu items are available for configuring...

Страница 49: ...on of both The following figure illustrates a simple pass though configuration This configuration does not use VLAN tagging or filter the Ethernet traffic Figure 23 PMP Basic Pass through Group Configuration The following diagram illustrates a network implementation using two VLAN groups The packets tagged with VID 107 are classified as data traffic while the packets tagged with VID 108 are classi...

Страница 50: ... SC 1 NA Notes 1 The Group ID Conn ID and Link ID values are assigned automatically and must be read from the screen after items are created 2 The QoS settings must be determined using the PMP Configuration Tool 4 3 3 Packet Classification The AN 80i PMP deployment can be configured for use with VLAN tagged traffic untagged traffic or a combination these two types Ingress packets received on the E...

Страница 51: ... data link with a remote end AN 80i Only one system in a wireless link must be set for Sector Controller mode PTP Sector Controller AN 80i begins transmitting automatically sends poll messages to locate remote AN 80i subscribers and negotiates operating settings for the link PTP Subscriber AN 80i waits passively monitoring the selected channel s until polled by the PTP Sector Controller Registrati...

Страница 52: ... automatically when a new link is added Peer MAC Enter the MAC address of the subscriber station The sector controller only registers a subscriber station if the MAC address has been entered using the link configuration screen Max DL Burst Rate Select the downlink burst rate for unicast traffic from the sector controller to the subscriber based on link budget calculations Max UL Burst Rate Select ...

Страница 53: ... known address or multicast unknown address Further processing is performed at the subscriber based on the Connection configuration Tagged Select tagged to associate a unique VID with this Group Packet received at sector controller Ethernet interface A packet with this VID has the matching outermost only VLAN tag removed The packet is forwarded over the wireless to all subscribers in this Group Pa...

Страница 54: ...oller Ethernet interface Uncheck this box to block all data traffic on the sector controller Ethernet interface The sector controller Ethernet port remains available for management traffic SS To SS Multicast Enable Check this box to enable group multicast traffic between subscribers Uncheck this box to block all multicast traffic between subscribers Wireless Traffic Parameters Changes to these set...

Страница 55: ... packets are handled on the subscribers Each subscriber can participate in multiple VLANs Figure 28 PMP Connection Configuration Screen Connection Configuration Connection Name Enter a name for this Connection 15 characters max The Connection name is displayed on configuration and statistics screens Connection ID Read only A unique Connection ID is generated automatically when a new link is create...

Страница 56: ...The default priority setting is used only when the Connection Tagging is set to pass through mode and the associated Group Tagging Mode is set to Tagged The Connection Default Priority value is used when adding the 802 1Q tag Group VLAN ID to the packet being forwarded Parent Link ID Enter the Link ID for this Connection This is the unique identification value created automatically when the subscr...

Страница 57: ...signed name for each link Config Click Config on any line to display the Link Configuration screen associated with that Link Status Click Status on any line to display the Link Statistics screen associated with that Link This includes uplink and downlink statistics for the link Expand Click Expand on any line to display the Connections browse screen showing all Connections associated with that Lin...

Страница 58: ...each Group Config Click Config on any line to display the Group Configuration screen associated with that Group Status Click Status on any line to display the Group Statistics screen associated with that Group This includes uplink and downlink statistics for the Group Expand Click Expand on any line to display the Connections browse screen showing all Connections associated with that Group Delete ...

Страница 59: ...ame User assigned name for each Connection Group Click the Group number i e 4 on any line to display the Group associated with this Connection Link Click the link number i e 5 on any line to display all Connections configuration for that link Config Configure Click Config on any line to display the Link configuration screen for that item Status Statistics Click Status on any line to display uplink...

Страница 60: ...cates if wireless link is operational Active YES Link Up Time Total time the wireless link has been operational Link lost Count Number of times link has been out of service Status Code Code indicating the condition of the AN 80i system Status indications are specific for PMP and PTP operation Configured Connections The number of Connections configured on this link Wireless The following statistics...

Страница 61: ...e the Group statistics screen to view statistics for all downlink traffic on Connections to this Group Click Groups in the menu to display the Groups browse screen Click Status to display downlink statistics for the selected Group Figure 33 PMP Group Statistics Screen General Group Name Name assigned to this Group Group ID Unique numeric identifier for this Group Packet Downlink Packets Discarded ...

Страница 62: ... to display statistics for the selected Group Figure 34 PMP Connection Statistics Screen General Name Name assigned to this Connection ID Unique numeric identifier for this Connection Packet Packets Discarded Number of Ethernet packets discarded could not be sent over the wireless interface Packets Transmitted Number of Ethernet packets transmitted over the wireless interface Packets Received Numb...

Страница 63: ...ration Guide This procedure is to aid configuring point to multipoint PMP operation on AN 80i systems For complete installation and operational procedures refer to the AN 80i System User Manual the AN 80i Quick Install Guide and the Installation Guidelines provided on CD ROM The VLAN tagging feature allows the user to configure and operate an AN 80i deployment as a VLAN aware wireless switch A gro...

Страница 64: ...settings 7 Repeat steps 1 6 for each subscriber station Step 2 Create Single Pass through Group 1 Click New Group to display the Group Configuration screen 2 Enter a unique name for this group in the Group Name field 3 Set the Group Tagging Mode to Pass through 4 Check the SC Ethernet Enable box 5 Set the Group QoS value for sending multicasts i e 5 A value of zero 0 disables all traffic 6 Use the...

Страница 65: ...tomatically by the AN 80i 4 7 2 VLAN Configuration Use these steps to convert the system from pass through operation to VLAN tagged connections Step 1 Change Group to VLAN Tagged 1 Click Groups to display the Groups Configuration screen 2 Click Config to edit the Group configuration 3 Set the mode to Tagged in the Group Tagging Mode field 4 Enter the VID for this group in the Group VLAN ID field 5...

Страница 66: ... del Delete an ID enable Enable an ID freq Enter frequency ranges for autoscan and DFS generate Create DSA RSA keys for SSH locally on AN 80i get Display the value of a statistic or parameter load Load commands logout End the current Telnet session new Create a new ID ping Send a ping message from the AN 80i system reboot Reboot the AN 80i reset Reset the AN 80i statistics values save Save the sel...

Страница 67: ...lnet session to the IP address of the AN 80i On a Windows PC open the Run command and type telnet followed by the IP address of the AN 80i When the command prompt screen appears login to the AN 80i The AN 80i may now be controlled using a set of CLI commands Figure 37 CLI Connecting via Telnet The system will logout users automatically if no commands are received idle for five minutes To exit imme...

Страница 68: ...k Del file file name mode Remove a file from flash and runtime memory name File name on server File name must be one of the following dsa_key_ mac pem DSA key used for SSH rsa_key_ mac pem RSA Key used for SSH ssl_cert_ mac pem SSL Certificate ssl_key_ mac pem SSL Key usr_wcert_ mac der User wireless certificate usr_wkey_ mac der User wireless key usr_wacert_ mac der User wireless authority certif...

Страница 69: ...mmand to generate a DSA or RSA key for use with SSH Table 26 CLI generate PTP PMP Parameter Description generate sshkey type Create keys of the specified type The keys are saved in flash and runtime memory type Can be dsa or rsa 5 3 7 Get Use the get command to view system parameters Use the following general format to view a parameter get field Enter Table 27 CLI get PTP PMP Parameter Description...

Страница 70: ...Number of active IDs activelinks Number of the active links boardtype Board type dldpkt Downlink discarded packets counter dlrpkt Downlink Rx packets counter dltpkt downlink Tx packets counter idenable ID status lactive Link active status ldlblk Downlink total blocks counter ldlbr Downlink burst rate ldldblk Downlink discarded blocks counter ldllfr Downlink lost frames counter ldlrblk Downlink ret...

Страница 71: ...urity keys information from file on FTP server server IP address of the TFTP server Files must be stored in the TFTP server default download directory name File name on server File name must be one of the following dsa_key_ mac pem DSA key used for SSH rsa_key_ mac pem RSA Key used for SSH ssl_cert_ mac pem SSL Certificate ssl_key_ mac pem SSL Key usr_wcert_ mac der User wireless certificate usr_w...

Страница 72: ...conn id id number 5 3 11 Ping Use the ping command to initiate an ICMP ping command from the AN 80i Table 31 CLI ping PTP PMP Parameter Description ping address Target IP address count Number of ICMP packets to send 1 16 5 3 12 Reboot Use the reboot command to reboot the AN 80i Table 32 CLI reboot PTP PMP Parameter Description reboot seconds Time to reboot the AN 80i seconds Time in seconds 0 canc...

Страница 73: ... be saved in the TFTP default directory The filename may be any name and extension valid for the TFTP server platform It is recommended use a filename that uniquely identifies the An 80i unit and the current date e g Red80 AD0023 080723 cfg See also loadscript command Table 35 CLI script PTP PMP Parameter Description script server TFTP server IP address name script file name 5 3 16 Set Use the set...

Страница 74: ...ified by the options key 2 executing a set command for this field will generate an error message autoscan Enable or disable the Autoscan function off Disable on Enable When enabled the PTP Subscriber system mode AN 80i automatically scans available channels to locate the current operating frequency of the PTP Sector Controller system Executing a set command this field on a PTP Sector Controller wi...

Страница 75: ...e is used to calculate the transmission to response interval and disregard reflections of the transmitted signal Used only if dstmod is set to manual dstmode Select the mode for determining the distance of the wireless link auto Distance is calculated automatically by the AN 80i manual Operator enters link distance dstmu Select the measurement unit for the link length dstmode mile dstmode units ar...

Страница 76: ...eature enables the AN 80i to request other Ethernet devices to pause transmission during busy periods off Disable on Enable gateway Enter the IP address of the default gateway on this segment gmt Enter the time offset from GMT i e 5 for EST grppri Group priority id id number pri VLAN priority grpqos Group QoS id id number qos QoS grprate Group rate id id number rate group rate grpvid Group VLAN ID...

Страница 77: ...he IP netmask noisethreshold Enter the maximum noise threshold 104 dBm to 65 dBm If the measured noise or interference level exceeds this threshold the equipment stops transmitting until the noise level is lower than this threshold optionskey Enter the options key string kIdx Index of the options key 0 1 kStr options_key_string peermac Peer MAC address id id number mac MAC address pllm Enable or d...

Страница 78: ...c Enter descriptive details about the location of this AN 80i The description can be any combination of up to 20 letters and numbers syslog Syslog enable setting off Disable syslog server protocol support on Enable syslog server protocol support syslogip Enter the syslog server IP address Valid only if syslog is enabled sysmode PTP Operation ptpsector controller The sector controller base station ...

Страница 79: ...all system configuration information Example 192 168 25 2 show config System Information sysname 1234567890 sysdescr b sysloc c syscontact d telnetport 23 snmp On snmptraps On snmptraplink On mgmtag Off mgmvid 0 Ethernet Configuration ipaddr 192 168 25 2 netmask 255 255 255 0 gateway 192 168 25 1 flowctrl Off sntp On sntpip 192 168 25 1 sntppoll 24 gmt 0 00 syslog Off syslogip 192 168 25 1 ethmode...

Страница 80: ... Link Enabled 27 SS 001 Data Conn Enabled 28 SS 001 Voice Conn Enabled links list of links Example 192 168 25 2 show links 26 Subscriber 001 Link log list the system log Example 192 168 25 2 show log 000d 00 00 00 1005 User Configuration Load OK 000d 00 00 00 1016 Options Key Properties Load OK 000d 00 00 00 1014 Options Key Load OK 000d 00 00 00 1018 Options Key Activated OK 000d 00 00 00 1001 Sy...

Страница 81: ...ysloc c syscontact d mac 00 09 02 00 bb 77 boardtype AN 80i Rev 1 0 radiotype T54i swver 10 00 023 other 10 00 019 sysuptime 8 day s 20 hr 19 min sysstarttime N A sysmode pmpsc rffreq 5490 0 txpower 10 chwidth 20 MHz rfstatus 0 Ethernet Statistics erxpkt 3081 erxpktd 0 etxpkt 8089 Wireless Statistics regstations 0 regconn 0 activelinks 0 activeids 0 Wireless Ethernet Statistics werxpkt 4592 werxpk...

Страница 82: ...to factory default settings snmpcommunity default idx Enter del Delete the specified community entry snmpcommunity del idx Enter print List all SNMP communities and associated permissions snmpcommunity print Enter 5 3 19 Snmptrap Use the snmptrap command to configure the SNMP trap message reporting Table 39 CLI snmptrap PTP PMP Description add add a new snmp trap to the snmp trap table The index v...

Страница 83: ...passwd field is available since the user can change only his own password The other commands are available only for members of the administrator Group Table 42 CLI user PTP PMP Description add Administrators can use this command to add new user accounts This option is available only for administrators user add username usertype Enter chgpasswd For the user accounts the chgpasswd command must be ex...

Страница 84: ...ggestions in this section please contact your local Redline representative Include the model name and serial number of the system in your communications 6 1 Factory Default Settings The following parameters are the factory default settings for the AN 80i Table 44 Diag Factory Default Settings Section Item Factory Default Setting System User Name admin Password admin Ethernet IP Address 192 168 25 ...

Страница 85: ...3 Restore power to the AN 80i PoE adapter and wait for 10 seconds 4 Power off the AN 80i PoE adapter for 5 seconds 7 seconds maximum 5 Restore power to the AN 80i PoE adapter and wait for approximately 20 seconds 6 Press the Enter key on the PC start the Telnet session When the login prompt appears you have approximately 30 seconds to login using admin as the user name and admin as password After ...

Страница 86: ...t settings displayed in the configuration screen The AN 80i will operate with these settings for a period of five minutes During the test period you may click the Save button at any time to save this configuration permanently also terminating the five minute timer After five minutes if the Save function button has not been applied the AN 80i will reboot and load the previously saved settings Attem...

Страница 87: ... Settings on page 85 The following table lists some common troubleshooting tips for the web interface Table 45 Diag Web Interface Diagnostics Symptom Possible Problem Solution General Information screen is not displayed Incorrect IP address and or Subnet Mask Perform a ping test from the host computer command line If the ping test is unsuccessful then the problem is with the IP address Perform a l...

Страница 88: ...were active the status code value would be 34 binary 100010 leading zeros are not displayed Table 46 Diag PTP Status Codes Error Type Error Decimal Error binary Description Tx Power 1 1 Power output is less than 10 dBm This message may appear before the RF link is established RF High Temp Warning 2 10 The transceiver internal temperature rose above 185F 85C The transceiver will shut down for 30 se...

Страница 89: ...c calculator that supports binary notation i e Windows on screen calculator Set the mode for Hex and enter the status code Change the mode to binary and match active bits 1 to the PMP Status Codes table For example if Radio Over Temperature bit 1 and PLL Error bit 4 were active the status code value would be Hex 12 binary 1 0010 Table 47 Diag PMP Status Code Bits 31 30 29 28 27 26 25 24 23 22 21 2...

Страница 90: ...o RF Band 5 470 5 725 GHz TDD 1 Rx Sensitivity 85 dBm 3 Mbps max Center Freq Steps 2 5 MHz 2 Channel Size PTP 10 20 40 MHz software selectable 1 PMP 10 20 MHz software selectable 1 T58 Radio RF Band 5 725 5 850 GHz TDD 1 Rx Sensitivity 85 dBm 3 Mbps max Center Freq Steps 2 5 MHz 2 Channel Size PTP 10 20 40 MHz software selectable 1 PMP 10 20 MHz software selectable 1 System Capability LOS Optical ...

Страница 91: ...802 3af 15 4 W Max Operating Temperature 40 C to 60 C Dimensions Weight 289 mm x 190 mm x 51 5 mm 11 38 in x 7 50 in x 2 03 in Humidity 0 to 95 Non condensing Weight 2 Kg 4 4 lb without bracket or antenna Storage Temperature 50 C to 70 C Compliance Safety IEC EN and UL CSA 60950 EMC EN 301 489 1 EN 301 489 17 5 8 GHz Radio Industry Canada RSS 210 FCC part 15 ETSI EN 302 502 5 4 GHz Radio w DFS Ind...

Страница 92: ...Order Gain Type Freq GHz Mounting Part Number dBi 3 3 3 8 4 9 5 0 5 15 5 35 5 25 5 35 5 4 5 8 Bracket A12015EAS 48 00065 00 15 120 panel 80i HD MNT 13 00043 00 A1815MTF 48 00012 00 18 15 panel 80i HD MNT 13 00043 00 A2014ARF 48 00054 00 20 13 8 panel 80i HD MNT 13 00043 00 A2209MTFD 48 00021 02 22 9 panel 80i LW MNT 13 00052 80i HD MNT 13 00043 00 A2212RWP 48 00030 00 22 12 parabolic 80i SA MNT 13...

Страница 93: ...l 80i HD MNT 13 00043 00 PA1590EASH 48 00053 00 15 90 panel 80i HD MNT 13 00043 00 PA1660EASH 48 00051 00 16 60 panel 80i HD MNT 13 00043 00 PA1760EAS 48 00050 00 17 60 panel 80i HD MNT 13 00043 00 7 4 Legacy Products Not Available to Order Table 52 Spec AN 80i Legacy Antenna Mounting Bracket Matrix Redline Order Gain Type Freq GHz Mounting Part Number dBi 3 3 3 8 4 90 5 00 5 15 5 35 5 25 5 35 5 4...

Страница 94: ...l polarization PA1760EAS 48 00050 00 17 60 3 3 3 8 GHz vertical polarization only PA1660EASH 48 00051 00 16 60 3 3 3 8 GHz horizontal polarization only PA1590EAS 48 00052 00 15 90 3 3 3 8 GHz vertical polarization only PA1590EASH 48 00053 00 15 90 3 3 3 8 GHz horizontal polarization only PA14120EAS 48 00059 00 14 120 3 3 3 8 GHz vertical polarization only PA14120EASH 48 00060 00 14 120 3 3 3 8 GHz...

Страница 95: ...8 00030 00 22 12 5 250 5 850 GHz parabolic PTP 8 A2804MTF 48 00024 00 28 4 5 5 15 5 875 GHz flat panel PTP 1 A2806RWP 48 00031 00 28 6 2 5 250 5 850 GHz parabolic PTP 1 A2906PWP 48 00063 00 29 6 4 900 5 875 GHz parabolic PTP 10 A3104RWP 48 00032 00 31 2 4 2 5 250 5 850 GHz parabolic PTP 1 A3204PWP 48 00064 00 32 4 4 900 5 875 GHz 3 ft parabolic PTP 3 7 5 4 5 15 5 35 GHz Radio ETSI Antennas The fol...

Страница 96: ...875 GHz flat panel PTP 20 12 7 26 2 A2806RWP 48 00031 00 28 6 2 5 250 5 850 GHz parabolic PTP 20 12 7 26 2 A2906PWP 48 00063 00 29 6 4 900 5 875 GHz parabolic PTP 20 12 7 26 2 A3104RWP 48 00032 00 31 2 4 2 5 250 5 850 GHz parabolic PTP 20 12 7 26 2 A3204PWP 48 00064 00 32 4 4 900 5 875 GHz parabolic PTP 20 12 7 26 2 A3403RWP 48 00033 00 34 6 3 4 5 250 5 850 GHz parabolic PTP 20 12 7 26 2 Table 58 ...

Страница 97: ...d selection must be professionally programmed and installed by the manufacturer or a trained professional installer The following table lists FCC and IC certified antennas Table 60 Spec FCC IC Antennas 5 25 5 35 GHz Operation Redline Order Part Number Gain dBi Description App Tx Power Setting dBm Tx Peak Conducted Power dBm Channel Size MHz Channel Size MHz 10 20 40 10 20 40 A36009MMO 48 00048 01 ...

Страница 98: ...ce The required antenna impedance is 50 ohms The RF output power and selection must be professionally programmed and installed by the manufacturer or a trained professional installer The following table lists FCC and IC certified antennas Table 62 Spec Antenna Tx Power Setting Combinations for FCC Redline Order Part Number Gain dBi Description GUI Setting for Channel dBm 3 5 MHz 5 MHz 7 MHz 10 MHz...

Страница 99: ...egional regulatory statutes Table 63 Spec Regional Identification Codes Regions Band DFS CBP Required 1 Channel Size MHz Channel Step MHz Start End 2 MHz Region 01 CALA Canada China Middle East US US 5 8 ISM No 10 2 5 5730 5845 20 2 5 5735 5840 40 2 5 5745 5830 Region 02 UK Jersey Norway UK 5 8G Yes 3 10 2 5 5730 5790 5820 5845 20 2 5 5735 5785 5825 5840 Region 03 EU CE 5 4G Yes 4 10 20 5500 5700 ...

Страница 100: ...340 40 2 5 5270 5330 Region 12 US US Yes 5 10 2 5 5260 5340 5 260 5 350 20 2 5 5265 5335 40 2 5 5280 5320 Region 13 Canada IC 5 3 G No 6 10 2 5 5260 5340 20 2 5 5265 5335 40 2 5 5280 5320 Region 14 No 5 1 3302 5 3797 5 7 1 3303 5 3796 5 10 1 3305 3795 14 1 3307 3793 20 1 3310 3790 28 1 3314 3786 Region 15 US FCC 3 6 G Yes 9 5 1 3652 5 3697 5 7 1 3653 5 3696 5 10 1 3655 3695 14 1 3657 3693 20 1 366...

Страница 101: ...ields are blank The operator may download a customer defined RSA and DSA key pair or use the default embedded certificate and private key identical for all AN 80i units Note that customer defined certificate and key files must conform to the filename format described in Table 66 Security User Key and Certificate Files For example SSL certificate file for AN 80i with MAC address 00 09 02 00 01 02 m...

Страница 102: ...s cryptographic module usr_wcert_ mac der User X 509 certificate for the wireless cryptographic module usr_wkey_ mac der User RSA key for the wireless cryptographic module Not used in v3 00 software release The following table lists the keys and certificates entered by the operator administrator Use the CLI commands load and del to add and remove files Use the CLI command generate to update the DS...

Страница 103: ...ertificate usr_wkey_ mac der User wireless key usr_wacert_ mac der User wireless authority certificate The mac portion is the MAC address of the board For example dsa_key_00 09 02 00 01 02 pem mode Can be usr or factory Defaults to usr if mode is not specified del file name mode Remove a file from flash and runtime memory name File name on server File name must be one of the following dsa_key_ mac...

Страница 104: ...ction such as disable transmission or use alternative frequency DHCP Dynamic Host Configuration Protocol A DHCP server automatically issues IP addresses within a specified range to devices on a network Directional Antenna An antenna that concentrates transmission power into one direction Encryption For the purposes of privacy the transformation of data into an unreadable format until reformatted w...

Страница 105: ...acket include the header the text and the trailer error detection and correction bits PHY Physical Layer Provides for the transmission of data through a communications channel by defining the electrical mechanical and procedural specifications PIR Peak Information Rate PMP Point to Multipoint PTP Point to Point QAM Quadrature Amplitude Modulation QPSK Quadrature Phase Shift Keying Receiver Sensiti...

Страница 106: ...70 00072 01 07 Proprietary Redline Communications 2010 Page 106 of 106 Sept 18 2008 302 Town Centre Suite 100 Markham Ontario Canada L3R 0E8 www redlinecommunications com ...

Отзывы: