Table 3
:
Wireless Signal LED Indication
Adaptive Modulation
Enabled
The Wireless Signal LED lights solid green when the wireless link is
operating at the rate equal to the Uncoded Burst Rate setting, and
blinks when operating at a lower rate.
Disabled
The Wireless Signal LED lights solid green when the wireless link is
established.
If the LED is off, it may indicate one of the problems listed in the following table:
Table 4
:
Wireless Signal LED Diagnostics
Symptom
Possible Problem
Solution
Weak RF
Link
Obstructions in the propagation path
causing signal degradation.
Try to remove obstacles or re-locate
antenna.
Antenna moved, due to high winds.
Re-align the antenna.
Ethernet Link LED
The Link LED lights solid green when there is an Ethernet connection and no traffic, and
blinks when traffic is detected. If the LED is off, it may indicate one of the problems listed
in the following table:
Table 5
:
Ethernet Link/Act LED Diagnostics
Symptom
Possible Problem
Solution
No Ethernet
Link
Poor cable connection to Ethernet
equipment.
Carefully check all cable connections.
Wrong type of cable to Ethernet
equipment.
If the Ethernet is connected to a
router, a straight-through cable is
required. If the Ethernet is connected
to a switch, a crossover cable is
required.
System processor malfunction.
Apply short reset or long reset.
The connected Ethernet equipment
may be malfunctioning.
Repair or replace faulty equipment.
Ethernet 100 LED
The Ethernet 100 LED lights solid green when the Ethernet port is operating at 100 Mb/s
and is off when operating at 10 Mb/s. If the LED is off, it may indicate one of the
problems listed in the following table:
Table 6
:
Ethernet 100 LED Diagnostics
Symptom
Possible Problem
Solution
Ethernet 10
Mbps
AN-80i is manually set for
10Base-T operation and
connected device is operating at
100Base-T or auto-negotiate.
It is strongly recommended to manually
configure all devices to matching speed
and duplex settings. If manual settings are
not available, both devices must be set to
auto-negotiate.
The connected Ethernet device is
operating at 10Base-T.
If the AN-80i is connected to a host
computer or server operating at 10Base-T,
this is normal operation.