User
AN-80i
Manual
70-00072-01-07
Proprietary Redline Communications © 2010
Page 31 of 106
Sept 18, 2008
IP Address
:
Enter the IP address for this AN-80i. The IP address is routable through the
Ethernet port and over the wireless interface.
IP Subnet
Mask
: Enter the IP subnet mask.
Default Gateway Address
:
Enter the IP address of the default gateway or router on the
Ethernet segment connected to the AN-80i Ethernet port.
Flow Control Enable
: Check this box
to enable flow control functions (802.3x) on the
AN-80i Ethernet port. Enabling this feature allows the AN-80i to request Ethernet
devices to pause transmissions during busy periods.
Prioritized Low Latency Mode Enable
: Check this box
to enable priority handling of
802.1p tagged traffic. When enabled, this ensures prioritized traffic is transmitted with
the lowest achievable latency, even under conditions of high IP data traffic loading.
Table 9
:
Web - 802.1p Priority Settings
Priority
Setting
Highest
6, 7
4, 5
0, 3, no tag
Lowest
1, 2
SNTP Enable
: Check this box
to enable the SNTP protocol support. This feature
allows AN-80i systems to time-stamp log messages using a network time server. When
enabled, you must enter the network address of the SNTP server in the SNTP Server IP
Address field.
SNTP Server IP Address
: Enter the network address of the SNTP server. Valid only
when the SNTP Enable field is checked.
Polling Interval
: Enter the SNTP polling interval (hours).
Time Zone (GMT)
: Enter the hours offset from GMT for this time zone. Valid only when
the SNTP Enable field is checked.
Syslog Enable
: Check this box
to enable the Syslog protocol support. This feature
allows AN-80i log messages to be saved in a central repository. When enabled, you
must enter the network address of the Syslog server in the Syslog Server IP Address
field.
Syslog Server IP Address
: Enter the network address of the Syslog server. Valid only
when the Syslog Enable field is checked.
Ethernet Mode
:
Select the operating mode of the Ethernet port.
Auto
- Auto-negotiate the speed connection speed.
10
- Operate at 10Base-T only.
100
- Operate at 100Base-T only.
HD
- Operate at half-duplex only.
FD
- Operate in full duplex only.
Important
: The auto-negotiate feature does not detect the speed and duplex of
manually set Ethernet equipment. The auto-negotiate feature works correctly only
when both communicating Ethernet devices are configured for auto-negotiate. Duplex
mismatches may result in an unexpected loss of communications.
It is recommended to manually configure Ethernet devices to 100Base-T / full duplex.