Valvola di Sicurezza 3 bar CE
PN10, TMAX 110°C
Attenzione! T 110°C
2
31
6-HYDRAULIC CONNECTION
Technical Dept. - All rights reserved - Reproduction is prohibited
SAFETY VALVE 3 bar
The boiler is protected against overpressures by a safety valve “2” fitted on the selected hydraulic kit. The safety valve drain must be
connected to a rubber pipe that can withstand a temperature of 110°C (not supplied) and that reaches the outside via an anti-odour
syphon. This drain is provided in order to prevent overpressures if the safety valve is opened.
Attention! The manufacturer of the appliance is not liable for any flooding caused by the safety valve being triggered
if it has not been joined properly to the outside of the product and to a proper collection and evacuation system.