Before connecting signal wires, the Timer Input logic jumper must be verified for proper position.
CAUTION
:
Timer Input common is NOT isolated from User Input common. In order to preserve the safety of the meter application, the timer input
common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth ground potential. If not,
hazardous voltage may be present at the User Inputs and User Input Common terminals. Appropriate considerations must then be given to the potential of
the User Input Common with respect to earth ground; and the common of the isolated option cards with respect to input common.
4.3
USER
INPUT
WIRING
Before connecting the wires, the Timer Input logic jumper should be verified for proper position. When the user input is configured for cycle count, in
module 4, the count input should be wired between terminals 7 & 10.
AC Power
Terminal 1: VAC
Terminal 2: VAC
1
2
AC
AC
1
2
+
_
+
-
DC Power
Terminal 1: +VDC
Terminal 2: -VDC
4
5
6
INPUT
A
INPUT
B
COMM
JUMPER
SNK
4
3
5
6
2.2K
:
COMM
+12V
INPUT
B
INPUT
A
JUMPER
SRC
NPN O.C.
3
4
5
6
COMM
+12V
INPUT
A
INPUT
B
JUMPER
SNK
PNP O.C.
3
4
5
6
+12V
COMM
INPUT
A
INPUT
B
JUMPER
SRC
4
5
6
+5V
COMM
DIODE
COMM
INPUT
B
INPUT
A
JUMPER
SNK
6
3
5
INPUT
A
INPUT
B
+12V
JUMPER
SRC
3
4
5
6
INPUT
A
INPUT
B
+12V
COMM
JUMPER
SRC
Two Wire Proximity, Current Source
Current Sourcing Output
Interfacing With TTL
Current Sinking Output
Switch or Isolated Transistor; Current Sink
Switch or Isolated Transistor; Current Source
Emitter Follower; Current Source
Sinking Logic
Terminal 7-9:
Terminal 10:
The user inputs of the meter are
internally pulled up to +12 V with 22
K resistance. The input is active
when it is pulled low (<0 .9 V).
}
Connect external switching device between
appropriate User Input terminal and User Comm.
COMM
USER 3
USER 2
USER 1
7
8
9
10
Sourcing Logic
Terminal 7-9: +VDC thru external switching device
Terminal 10: - VDC thru external switching device
The user inputs of the meter are internally
pulled down to 0 V with 22 K resistance.
The input is active when a voltage greater
than 3.6 VDC is applied.
7
8
10
9
+
-
(30V max.)
SUPPLY
V
COMM
USER 3
USER 2
USER 1
JUMPER
SRC
JUMPER
SNK