background image

STAIRCASE LIGHTING TIMER ASM-03 

INSTRUCTION MANUAL

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

VER. 001_03.04.2012

APPEARANCE

The device is designed for 

one-phase installation and

must be installed in accor-

dance with standards valid

in a particular country. The 

device should be connected

according to the details inclu-

ded in this instruction manual. Installation, con-

nection and control should be carried out by a 

qualified electrician staff, who act in accordan-

ce with the instruction manual and the device 

functions. Disassembling of the device is equal 

with a loss of guarantee and can cause elec-

tric shock. Before installation make sure the 

connection cables are not under voltage. The 

cruciform head screwdriver 3,5 mm should be 

used to install the device. Improper transport, 

storage,  and  use  of  the  device  influence  its 

wrong functioning. It is not advisable to install 

the device in the following cases: if any device’s 

part is missing or the device is damaged or de-

formed. In case of improper functioning of the 

device contact the producer.

CAUTION

FEATURES

TECHNICAL DATA

DESCRIPTION

ASM-03

Input (supply) terminals: L, N

Input rated voltage: 230 V AC

Input voltage tolerance: -15 ÷ +10 %

Power/relay supply indicator: green  LED

Nominal frequency: 50 / 60 Hz

Rated power consumption: 25 mA

Supply/release terminals: IN, IN, IN 

Supply/release control current: 300 µA

Threshold adjustment time: 3 min ÷ 30 min (rotating potentionometer)

Operation mode: ON, AUTO, OFF

Time accuracy adjustment: ±10 %

Time repeatability adjustment: ±5 %

Relay indicator: LED red

Output contacts parameters: 1NO - 16 A / 250 V AC1 4000 VA

Number of terminal clamps: 8

Section of connecting cables: 0,2 ÷ 2,50 mm

2

Ambient temperature range: -20 ÷ +45 

o

C

Operating position: free

Mounting: TH rail 35 (EN 60715)

Casing protection degree: IP20 (EN 60529)

Protection level: II

Overvoltage category: II

Pollution degree: 2

Surge voltage: 2 kV (EN 60669-1), 1 kV (EN 61000-4-5)

Dimensions: monomodular (17,5 mm) 90x17,5x66 mm

Weight: 76 g

Reference standards: EN 60669-1; EN 60669-2-1

EN 61000-4-2,3,4,5,6,11

●  Staircase lighting control

●  Fluent operating time adjustment 

from 3 to 30 minutes

●  Relay indicator: LED red

●  Input rated indicator : LED green

●  Mode setting option: continuous work 

mode (ON), or continuous work mode 

OFF

●  Cooperation with unipolar illuminated 

pushbuttons

●  Con-blockade function

●  Voltage relay output – one joint of 

max 16 A load

●  Monomodular casing

●  Mounting on TH 35 rail

Staircase lighting timer ASM-03 is 

used for staircase and hall lightning 

controlling. After a signal it switches on 

the lightning for a set time and then au-

tomatically switches off. Working can be 

smoothly regulated from 3 to 30 min by 

potentionometer placed on front panel of 

the automat. 

ASM-03 is equipped with 

con-blockade function and ON/OFF 

function. 

O

 

u

 

t

 

p

 

u

 

t

 

 

 

r

 

e  

l  

a  y   

Switch on adjustment

Input rated signalization

Input terminal (L)

Input terminal (N)

Relay indicator signalization

ON/AUTO/OFF function

Output terminals (IN,IN,IN)

terminals (11,11,14)

The symbol stands for selective 

collection of electrical and 

electronic devices. Placing used 

devices with other waste is not 

allowed

Отзывы: