Bulletin No. PAXCK-J
Released 2018-05-15
Drawing No. LP0524
-17-
the parameters for Setpoint 1 (
) in Module 6 are automatically
configured to implement the selected operating mode. For some modes,
parameters in Modules 1 and 2 are also automatically configured to
properly implement the predefined mode. Refer to the chart shown with
the timing diagrams for the specific parameters loaded for each
predefined mode. Also, note the specific external wiring or plug jumper
settings required for some modes.
The Setpoint On/Off or Time-out values for the specific application
should be entered directly in Module 5 after selecting the operating mode.
Only the value parameters which apply to the selected mode are
displayed. These values can also be entered through Module 6, Setpoint
(Alarm) Parameters, if desired.
Select
if not using a Predefined Operating Mode, in which case
Setpoint parameters must all be individually programmed for the
particular application.
Timing Diagrams for Predefined Timer Operating Modes
NOTE
: Input A is shown as a Sourcing input (active high). If a Sinking input (active low) is used, the logic levels for Input A would be inverted.
Input A
Output 1
T1
T2
T
T1
Input A
Output 1
T
T
Input A
Output 1
T
T
Input A
Output 1
T
T
Input A
Output 1
T
T
Input A
Output 1
T1
T
T2
On-Delay Timing
On-Delay / Interval Timing
Repeat Cycle Timing
Interval Timing (Edge triggered)
Off-Delay Timing
Interval Timing (Level triggered)
The input signal must be wired to both the Input A and
User Input 1 terminals. The Timer Input plug jumper and
the User Input plug jumper must both be set to the
same position (either both SNK or both SRC).
The input signal must be wired to both the Input A and
User Input 1 terminals. The Timer Input plug jumper and
the User Input plug jumper must be set to opposite
positions (one SNK, one SRC) and the Input signal must
be a current sinking type (i.e. pulls input to common).
Parameter Settings for Predefined Timer Operating Modes
MODULE 1 - Timer Input Parameters (
*/1
)
MODULE 2 - User Input Parameters (
'/$
)
MODULE 6 - Setpoint Parameters (
41U
)
161
-JU
0S4E
"6U0
UTU1
U06U
410G
0'G
41
0/
0''
0''
0''
0''
0''
0''
Power-up State
/0S
/0S
/0S
/0S
/0S
/0S
Setpoint Annunciator
/0
/0
/0
/0
/0
/0
Output Reset w/display Reset
/0
/0
/0
0''
/0
/0
Timer/Counter Auto Reset
0''
0''
0''
/0
0''
/0
Timer Stop
T*
N/A
T2*
N/A
N/A
N/A
Time-out Value
N/A
T*
N/A
T2*
T*
N/A
Setpoint Off Value
N/A
7"-6&
N/A
7"-6&
7"-6&
N/A
Setpoint Off
N/A
N/A
T1*
T1*
N/A
T*
Setpoint On Value
U4USU
U4USU
7"-6&
7"-6&
U4USU
7"-6&
Setpoint On
/0S
/0S
/0S
/0S
/0S
/0S
Output Logic
U06U
0/0''
U06U
0/0''
0/0''
-"U$)
Setpoint Action
UE41
UE41
UE41
UE41
UE41
UE41
Setpoint Assignment
41
41
41
41
41
41
Setpoint Select
*/U&
*/U-
E-:*/U
S&1&"U
0'E-:
0/E-:
PARAMETER
06U
"$U
"4/
414&-
DISPLAY
&ES4
&ES4
&ES4
-&7S4U
&ES4
&ES4
Timer Input Operation
S&1&"U
E-:*/U
*/U&
*/U-
0'E-:
0/E-:
PARAMETER
*/101
DISPLAY
/0
N/A
0S4U&
/0
N/A
/0
N/A
/0
S4U-
/0
N/A
Reset Key
User Input 1
*/U&
*/U-
E-:*/U
S&1&"U
0'E-:
0/E-:
PARAMETER
S4U
64&S
DISPLAY
* Refer to timing diagrams. These parameters are the actual Setpoint On/Off or Time-Out values set by the user for the specific application.
(
41:&4
)
/0