DIGITAL TIMER

TEMPUSE03-04T

-15396

5. INDICATORS AND KEYS

1. DESCRIPTION

A digital timer/counter with programmable time base that operates in both cyclical functions as well as in 
functions that are triggered by a key/switch. It has an internal audible alarm (buzzer) and an output to 
activate the process finish alarm and event totalizer. The 

Tempus

e

 

allows you to set up to three 

presets for the timer and counter modes, in addition to the configuration of a delay between timer cycles 
where two outputs remain off. It also features a digital input to start the cyclical timer, different time units 
for on and off times in the cyclical timer mode, event accumulator for the timer/counter modes, and 
counter mode for low frequency counting with dry contact.
Product conforming to UL Inc. (United States and Canada).

 

2. SAFETY RECOMMENDATIONS

- Check the controller for correct fastening;
- Make sure that the power supply is off and that it is not turned on during the controller installation;
- Read the present manual before installing and using the controller;
- Use adequate Personal Protective Equipmenet (PPE); 
- For application at sites subject to water spills, install the protecting vinyl supplied with the controller;
- The installation procedures should be performed by a qualified technician.

3. APPLICATIONS

  

• Ovens, injection machines, defrost control
• Process monitoring and control.
• Rewinders
• Packing machines
• Electric panels in general

evolution

 

 

Tempus

e

 

 

V

er

.03

(*)

Acceptable variation in relation to the rated voltage.

4. TECHNICAL SPECIFICATIONS

Electric supply

TempusE: 

115 or 230 Vac ±10%(*)(50/60 Hz)

Operating temperature

 

0 to 50 ºC / 32 to 122°F

Operating humidity

10 to 90% RH (no condensation)

Dimensions (mm)

76 x 34 x 77 mm (WxHxD)

Maximum current per output

OUT1: 

16(12)A 250Vac 1HP

 OUT2: 

10A / 250Vac ¼ HP

Dimensions for cutting - to fasten 
the instrument

71 ± 0,5 x 29 ± 0,5 mm (see image V)

Set key

Quick Access 
Menu Key (Flatec)

Upper Key

Lower Key

Indication of OUT1 output activated

Indication of OUT2 output activated

Image I: TempusE - 115Vac

115 Vac

6. WIRING DIAGRAM

6.1. Identifications (see Images I and II)

-

 

Image I:

 TempusE, supplied at 115 Vac. 

-

 

Image II:

 TempusE, supplied at 230 Vac. 

Image II: TempusE - 230 Vac

230 Vac

CONTROLLER

WIRING
TERMINALS

WIRING
TERMINALS

POWER
GRID

CONTROLLER

WIRING
TERMINALS

WIRING
TERMINALS

NC

}

POWER
GRID

}

COMMON OUT1

Tempus

e

IMPORTANT

INSTRUMENTS  IN  THE  EVOLUTION  SERIES  HAVE  TWO 
DIFFERENT  TERMINAL  SIZES,  BUT  BOTH  ARE  COMPATIBLE 
WITH  THE  SCREWDRIVER  2.0MM.  USING  THE APPROPRIATE 
TOOLS DURING INSTALLATION ENSURES A LONGER LIFE AND 
THE PROPER OPERATION OF THE PRODUCTS.

Surge Protective Device (SPD)

(sold separately)

W i r i n g   d i a g r a m   f o r  
instalation  of  SPD  in 
magnectic contactor 

A1 and A2 are the terminals 
of the contactor coil.

W i r i n g   d i a g r a m   f o r  
instalation  of  SPD  in  line 
with loads

For  direct  drive  take  in  to 
consideration  the  specified 
maximum current.

A1

A2

SPD

6.2. Controller power supply

Use the pins according to table below, considering the set version:

6.3. Recommendations of IEC60364 standard

a) 

Install overload protectors in the controller supply.

b) 

Install transient suppressors - suppressor filter RC - in the circuit to increase the service life of the 

controller relay. See connection instructions of the filter on the previous page.

7. FASTENING PROCEDURE 

a)

  Cut  out  the  panel  plate  (Image  V  -  item  14)  where  the  controller  shall  be  fastened,  with  sizes                               

X = 71±0.5 mm and Y = 29±0.5 mm;

b)

 Remove side locks (Image VI - item 14): to do that, compress the central elliptical part (with the Full 

Gauge Controls logo) and displace the locks backwards;

c)

 Introduce the controller in the notch made on the panel, inwards;

d)

 Place the locks again and then displace them until they compress into the panel, fastening the 

controller to the housing (see arrow indication in Image VI - item 14);

e)

 Perform the electric installation as described in item 6;

f)

 Adjust the parameters as described in item 10.

       ATTENTION: for installations requiring liquid tight sealing, the notch sizes for the controller 
installation should be no more than 70.5x29mm. The side locks should be fastened so that they 
press the sealing rubber avoiding infiltration between the notch and the controller.
Protector vinyl - Image VII (item 14)

It protects the controller when installed at a site subject to water spills, such as refrigerated counters.
This adhesive vinyl is supplied with the instrument in the package.

       IMPORTANT: Make the application only after completing the electrical connections.
a) 

Retreat the side locks (Image VI - item 14);

b) 

Remove the protective film from the adhesive vinyl face;

c) 

Apply the vinyl over the entire upper part, bending the flaps, as indicated by the arrows - Image VII 

(item 14);

d) 

Reinstall the locks.

NOTE: 

The vinyl is transparent, allowing visualization of the wiring system of the instrument

Pins

TEMPUS E

9 and 10

9 and 11

115 Vac
230 Vac

Degree 

of protection

IP 65

FRONT

Buzzer

Serial 

programming

Precision (timer/cyclical timer)

 

0,05% FE

Maximum frequency (counter)

 100cps - counts per second (100 Hz)

NC

COMMON OUT2

OUT1

OUT2

OUT2

COMMON OUT1

OUT1

ST

ART/P

AUSE

COUNT IN

ST

OP/

RESET

ST

ART/P

AUSE

COUNT IN

ST

OP/

RESET

Counter input

 

NO/NC (dry contact) No - voltage input

Load

SPD

OUT2

OUT2

COMMON OUT2

Tempus

Tempus

E251415