Assembly
Connecting the drive unit to the forestay
38
5.5.5 Connecting the foil to the drive unit
Notice
Risk of corrosion of the foil
Corrosion will lead to destruction of the foil.
−
Apply Tef-Gel or another galvanic corrosion inhibitor to the surfaces of the foil and the
furler drive adapter in contact with each other.
1. Insert the split bottom bushing into the feeder section.
2. Apply Tef-Gel to the bottom 10 cm of the feeder section and to the inside surface of the furler
drive adapter on the drive unit.
3. Place the threaded plate in the recess in the feeder section.
4.
Slide the drive unit over the forestay and the feeder section.
5.
Secure the feeder section in the furler drive adapter with two cap screws. (R6, R7: screw on
using three screws.)
Pos: 48 /ZINDEL/Rollreffanlagen/Montage/rod/Rodvorstag fixieren @ 1\mod_1401092898727_13349.docx @ 13970 @ 3 @ 1
5.5.6 Securing the rod forestay
1. Insert the forestay through the drive unit until the rod collet can be mounted on the forestay.
2. Grease the rod collet halves.
3. Mount the rod collet halves on the forestay and screw the rod collet all the way into the drive
unit.
4.
Pull the forestay back into the drive unit until the rod head is situated in the rod collet.
Pos: 49 /ZINDEL/Rollreffanlagen/Montage/wire/Drahtseilvorstag fixieren @ 1\mod_1401094042287_13349.docx @ 13971 @ 3 @ 1
Содержание RF90
Страница 4: ...Notes www reckmann com ...
Страница 74: ...Notes 70 ...