![reci FCA Series Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/reci/fca-series/fca-series_user-manual_1426702024.webp)
Beijing Reci Laser Technology Co., Ltd
User Guide for FCA Series Hand Laser Welding System
23
(4) Touch and input the required process parameters through the main interface of the touch
screen and the auxiliary parameter setting interface. After the interface returns to the "Setup
successful" prompt, click "Confirm".
(5) Touch to set the laser "Work mode" to series or spot welding through the main interface of
the touch screen.
(6) Clamp the workpiece clamp on the workpiece or plate to be processed.
(7) Short the weld head and the workpiece clamp, and simulate the processing process through
the red indicator light.
(8) Press the button of the weld head, and turn on the laser according to the set parameters.
(9) After the processing is completed, release the button of the weld head, and turn off the
laser according to the set parameters.
(10) If the current parameter is suitable for the current workpiece, the parameter can be saved
on the touch screen, and it can be selected directly next time.
(11) If you need to adjust the process parameters, repeat steps (3) ~ (7).
Notice:
The parameter storage and selection can only be 2 digits, and the previously saved parameters
will be overwritten when the storage name is repeated.
4.7
PC Model
4.7.1
Settings and Connections
Figure 4.7 The connection of PC model