Beijing Reci Laser Technology Co., Ltd
User Guide for FCA Series Hand Laser Welding System
22
on the laser through the "Laser en" on the main interface of the screen. Then, set the working
parameters of the laser through the main interface of the screen and the auxiliary parameter
interface. Then, through the main interface of the display "Work mode" to select the laser working
mode: series or spot welding; finally, the laser and red indicator light switch are controlled by the
button of the weld head. After the button is pressed and closed, the laser outputs and the red
indicator light is turned off. When the button is turned off, the laser is turned off and the red
indicator light outputs.
Notice:
For safe, the weld head and the work clamp must be short-circuited before the laser output.
4.6
Touch screen Mode
4.6.1
Settings and Connections
Figure 4.6 The connection of touch screen model
4.6.2
Sequence of operations
(1) If you need to connect a wire feeder, please connect the wire feeder that meets the
requirements to the corresponding port on the rear panel of the laser before powering on.
(2) Turn on the power supply of the device, turn on the air switch on the rear panel of the
device, and wait for the initialization of the device for 10 seconds.
(3) Turn on the laser output function through the "Laser en" in the main interface of the touch
screen.