Beijing Reci Laser Technology Co., Ltd
User Guide for FCA Series Hand Laser Welding System
10
Cooling water quality
The laser adopts air-cooled heat dissipation. Please
operate the equipment in a place with good air circulation,
and ensure that the distance between the left and right sides
and the top of the equipment and the wall is > 10cm, and no
objects blocking the exhaust can be placed on the top.
The inlet air pressure of the gas pipe shall not be greater
than 0.7MPa.
Note:
(1) The output head of the laser is connected with the armor. Please check the output head carefully
to prevent dust or other pollution. Please use special lens paper when cleaning the lens at the
output end..
(2) Never installing the laser output with the processing system when the equipment is power on.
(3) The protective glasses should be worn all the time.
CAUTION
:
Never make this product work in high humidity
(>
85%
)
,though the products
have an excellent adaptability to the high humidity environment.
NO
SYMBOL
IMPORTANT :
The lifetime of the laser will be shortened and the output power will degrade
while the cooling system working at a higher temperature for too long time.
Please ensure the cooling system is enough and the temperature is suitable.
2.5
Instructions for use
(1) Before supplying the power to the device, make sure the power supply and the connection
of all wires are correct (See table 2.2 and subsection 4.3).
(2) Keep the outer black cap covered while the device is not in use, dust-proof should not be
absent any time.
(3) There is no warranty in case of no following this instruction.
2.6
Characteristic Parameters
The characteristic parameters of the FCA series fiber laser which the power is ranged from
1000W to 3000W is demonstrated in the table.