Beijing Reci Laser Technology Co., Ltd
User Guide for FCA Series Hand Laser Welding System
32
NO
MESSAGE
DESCRIPTION
SOLUTION
8.
IdleCur2
Fault
The current value when the
laser is turned off exceeds the
upper limit.
Restart the laser. If it happens frequently,
please contact our after-sales service
personnel.
9.
CurHard1
Fault
The current value exceeds the
hardware threshold.
Check if the 220V AC power supply of
the laser is stable. If it is stable, reduce
the peak output power of the laser. If the
fault still occurs, please contact our
after-sales service personnel.
10.
CurHard2
Fault
The current value exceeds the
hardware threshold.
Check if the 220V AC power supply of
the laser is stable. If it is stable, reduce
the peak output power of the laser. If the
fault still occurs, please contact our
after-sales service personnel.
11.
Trial Expires
Fault
Trial time limit exceeded.
Contact our after-sales service personnel
to see if you can continue to use the
laser.
12.
Timing Chip
Fault
The timekeeping chip faults.
Please contact our after-sales service
personnel.
13.
Over Power
Fault
The power consumption of the
driver board exceeds the
maximum value.
Check if the 220V AC power supply of
the laser is stable. If it is stable, but the
fault still occurs, please contact our
after-sales service personnel.
14.
T1 Fault
The temperature at the pump
source exceeds the upper
temperature limit.
When confirming that the working
environment of the laser is lower than the
usage requirements, restart the laser. If
the fault still occurs, please contact our
after-sales service personnel.
15.
T2 Fault
The temperature at the fiber
exceeds the upper temperature
limit
When confirming that the working
environment of the laser is lower than the
usage requirements, restart the laser. If
the fault still occurs, please contact our
after-sales service personnel.
16.
T3 Fault
RESEVED
RESEVED
17.
T4 Fault
RESEVED
RESEVED
18.
No Gas
Fault
The air pressure at the GAS IN
is lower than the set value.
Ensure that the air pressure at the GAS
IN is greater than 5L/min, restart the
laser, If the fault still occurs, please
contact our after-sales service personnel.
19.
Power Supply
Fault
The power supply is abnormal.
Check if the 220V AC power supply of
the laser is stable. If it is stable, but the
fault still occurs, please contact our
after-sales service personnel.